What a Sorensen harvester liposuction cannula is
Look closely at the holes on this harvester and you will see they are not plain round drillings. Each one is cut at a slant through the wall, so it has an edge on one side. In our photograph they sit in two rows behind a rounded tip, five in the upper row in view and five in the lower, each one set between two of the other.
Google AI Mode, read on 18 November 2026, describes the Sorensen harvester liposuction cannula as a multi port microfat harvesting instrument whose beveled micro ports take uniform, fine fat parcels for delicate fat transfer. It says the edges cut on both the forward and the backward stroke, and that the fat they take passes smoothly through fine micro injectors. It names the face and the area around the eyes, the breast, and, in the larger sizes, body harvesting.
Buyers search for it as a Sorensen cannula, and Gemini, read the same day, lists it as a Sorensen fat harvesting cannula. Described rather than named, it is a harvester liposuction cannula with beveled ports, which is what the words on our own web address say.
Key design features
Small beveled ports
Each port in our photograph is cut on a slant, which leaves a fine edge on one side of the opening. The edge takes small pieces of fat as the cannula moves, rather than waiting for the suction to pull them in, and small pieces are what a fine graft needs.
Two staggered rows
The upper and lower rows are offset, so the ports cover the end of the tube evenly instead of lining up. The cannula draws from more than one face without being turned in the hand.
Five ways to finish the back end
The order form offers five ways to finish the back end: a super fix handle in style A or style B, an aluminum Luer lock, a super Luer lock, or a Toomey hub. There is no steel Luer lock and no threaded fitting on this one. The aluminum Luer lock screws onto a syringe or a Luer handle. The Toomey hub takes a 60 cc Toomey syringe for harvesting by hand, and the super fix handles make the cannula one piece for a suction line. The hub sets the price: 22 dollars with the aluminum Luer lock, 32 with the super Luer lock, 37 with the Toomey hub, and 45 or 55 with a super fix handle.
The hub decides the lengths
Our form keeps two size lists. With a Luer lock or the Toomey hub it runs from 2 mm in 15 and 20 cm up to 5 mm in 35 cm. With a super fix handle it adds 3 mm in 35 cm and 4 mm in 15 and 20 cm. Pick the hub first, and the form shows only what it can make.
Which size to order
Every size below was read off our own order form on 18 November 2026. The size does not change the price; only the hub does. Pick the hub first, because it decides which lengths the form shows.
| Diameter | Lengths with a Luer lock or Toomey hub | Lengths with a super fix handle |
|---|---|---|
| 2 mm | 15 cm, 20 cm | 15 cm |
| 2.4 mm | 15 cm, 25 cm | 25 cm |
| 3 mm | 15 cm, 20 cm, 25 cm, 30 cm | 15 cm, 20 cm, 25 cm, 30 cm, 35 cm |
| 4 mm | 25 cm, 30 cm, 35 cm | 15 cm, 20 cm, 25 cm, 30 cm |
| 5 mm | 25 cm, 30 cm, 35 cm | 25 cm, 30 cm, 35 cm |
Where it is used
The first two columns come from the AI Mode answer and from Gemini, both read on 18 November 2026. They describe the pattern in general, not our measurements. The last column is our own guide to our sizes.
| Use | What the answers say it is for | Where our sizes fit |
|---|---|---|
| Facial grafting | Fine fat for the tear troughs, lips and cheeks | 2 and 2.4 mm, 15 to 25 cm, on a Luer lock |
| Breast transfer | Fat for breast augmentation and reconstruction | 3 and 4 mm, on a Toomey hub |
| Body harvesting | Larger diameters for body donor sites | 4 and 5 mm, 25 to 35 cm |
| Abdominal donor site | Named by Gemini for viable fat | 3 and 4 mm, 20 to 30 cm |
| Fat for further processing | Fine parcels that pass through micro injectors | 2 and 2.4 mm, on a Luer lock |
What it is for, and what it is not for
The Sorensen is a fine harvester. The table names the jobs where another cannula of ours suits better.
| Job | Use the Sorensen? | What to use instead or beside it |
|---|---|---|
| Fine fat for delicate transfer | Yes | This is the job it is made for |
| Larger amounts of fat for the body | In the larger sizes | Or our large volume harvester cannula |
| Harvesting through fibrous fat | Not its job | Our harvester cannula with raised edge ports |
| Putting the fat back in | No | A fat injection cannula from our fat transfer range |
| A steel Luer lock or a threaded fitting | Not offered on this form | The aluminum Luer lock or the super Luer lock |
How it compares with the rest of the harvester family
Six harvesters make up this family on our site. The second column is read off each listing’s own photograph, and the last off each product’s order form, on 18 November 2026.
| Pattern | What the tip carries, from our own photograph | What that is for | On our order form |
|---|---|---|---|
| Large volume harvester | long oval ports in two staggered rows along the end | taking larger volumes of fat for grafting | 2 to 5 mm, 15 to 35 cm, 7 hub styles |
| Sattler tip | many small round holes in rows behind a rounded tip | fine fat for small grafts | no size or hub choice on the listing, so tell us both when you order |
| Sorensen harvester (this page) | small slanted holes in two staggered rows | fine, even fat for transfer | 2 to 5 mm, 15 to 35 cm, 5 hub styles |
| Harvester, raised edge ports | small ports, each with a raised, pointed edge | harvesting through fibrous fat | 2 to 5 mm, 15 to 35 cm, 7 hub styles |
| Blugerman II | small round holes along a long stretch, with one slot part way along | harvesting and debulking over a longer stretch | 2.4 to 5 mm, 15 to 35 cm, 7 hub styles |
| Blugerman I | small round holes near the tip, then one slot behind them | harvesting from a shorter stretch of shaft | no size or hub choice on the listing, so tell us both when you order |
Materials and finish
Every Sorensen harvester cannula we make is formed from high quality medical grade stainless steel. The steel itself is made to a German specification. We do not publish a grade number.
The beveled ports are cut through the wall of the tube, and their edges are what take the fat in. On the aluminum Luer lock the hub is aluminum. The hub changes how the cannula connects and nothing about the tip.
Caring for it
Flush the Sorensen harvester liposuction cannula as soon as it comes out of use, before fat sets in the lumen. A beveled port holds tissue against its edge, so flush each row from the outside with a syringe, then push a fine brush through the full length of the lumen. Look through the tube against a light to be sure it is clear. Dry it, steam sterilize it on the normal instrument cycle, and store it straight.
Ordering and wholesale
The Sorensen harvester liposuction cannula is made by Adas Instruments in our own workshop and sold direct, which is why the price sits where it does against the catalog houses. Order one for a single tray, or in quantity for a hospital list or a distributor line. We do OEM work under your own brand and your own item numbers. Send us a sample and we will hold a run to your pattern rather than ours. Stock items ship from our own workshop. Backorder items take 10 to 12 working days to make. Every instrument carries a three year replacement warranty against manufacturing defects. Production is controlled under an ISO 13485 quality management system.
Frequently asked questions
What is a Sorensen harvester liposuction cannula used for?
It is used to take fine, even fat parcels for delicate fat transfer. The AI Mode answer we read names the face, the tear troughs, the lips and cheeks, and breast transfer, with the larger sizes used on the body. Which cases it suits is the surgeon’s call.
What makes the ports on a Sorensen harvester liposuction cannula different?
They are beveled: each is cut at a slant through the wall, so it has a fine edge on one side. AI Mode says the edges cut on both the push and the pull. Our photograph shows them in two staggered rows behind a rounded tip.
What size Sorensen harvester liposuction cannula should I order?
That depends on the area and the surgeon. We make it from 2 to 5 mm and from 15 to 35 cm, and the size table above shows which lengths come with which hub. The fine sizes suit the face; the larger ones suit body donor sites.
Can a Sorensen cannula be used with a syringe?
Yes. Choose the Toomey hub for a 60 cc Toomey syringe, or the aluminum Luer lock or super Luer lock for a smaller syringe. For a suction line choose a super fix handle. There is no steel Luer lock and no threaded fitting on this form.
How is it different from the Sattler tip?
Both take fine fat through many small ports. Our Sattler tip has small round holes in rows and no size choice on its listing. The Sorensen has beveled ports in staggered rows and a full order form from 2 to 5 mm with five hubs.
Related products and categories
Three more patterns from the harvester family: harvester cannula, Blugerman II liposuction cannula and Blugerman I liposuction cannula. The whole range is in aspiration cannulas, and the handles, adapters and sets that go with it are under liposuction cannulas and accessories.











Reviews