Accelerator Liposuction Cannula: Engineered for Rapid Fat Harvesting
The Accelerator Liposuction Cannula from Adas Instruments represents the pinnacle of efficiency in modern aesthetic surgery. This high-capacity fat suction cannula is meticulously designed for practitioners who require a fast-action tool for large-volume fat extraction. It is widely recognized as a premier fat harvesting cannula that ensures flawless surgical execution in every reconstructive workflow and fat suction tool application.
The Accelerator Liposuction Cannula is uniquely handcrafted to ensure a perfectly balanced weight distribution between the hub and the distal tip. Every instrument undergoes a specialized polishing process to create an ultra-smooth internal lumen, ensuring that the high quality suction cannula provides a lifetime of surgical reliability and unmatched resistance to biological buildup during intensive fat transfer procedures.
Advanced Surgical Grade Construction
Constructed from high-tensile premium medical grade steel, this cannula offers exceptional durability and resistance to bending under vacuum pressure. The Accelerator fat suction tool is engineered with a smooth, non-traumatic tip that provides superior tactile sensitivity, allowing the surgeon to navigate various tissue layers with ease. This professional-grade liposuction harvesting tool is treated with an electrochemical passivation process, ensuring it remains a corrosion-resistant staple among your liposuction instruments. The tapered shaft is specifically balanced for ergonomic manipulation, significantly reducing hand fatigue during long body sculpting sessions. As a key component of our fat grafting tools collection, it excels in minimizing tissue trauma while enhancing procedural speed.
Care and Maintenance
- Cleaning: Initiate ultrasonic cleaning immediately following surgery to remove cellular debris from the internal lumen and ports.
- Sterilization: Fully autoclavable. Standard cycle: 134°C (273°F) for a minimum of 3.5 minutes.
- Internal Flushing: Use a specialized cannula brush and enzymatic cleaner to maintain fluid instrument motion.
- Inspection: Regularly examine the suction ports for nicks and verify that the connection hub locks securely.

Accelerator Liposuction Cannula: Engineered for Rapid Fat Harvesting
The Accelerator Liposuction Cannula from Adas Instruments represents the pinnacle of efficiency in modern aesthetic surgery. This high-capacity fat suction cannula is meticulously designed for practitioners who require a fast-action tool for large-volume fat extraction. It is widely recognized as a premier fat harvesting cannula that ensures flawless surgical execution in every reconstructive workflow and fat suction tool application.
The Accelerator Liposuction Cannula is uniquely handcrafted to ensure a perfectly balanced weight distribution between the hub and the distal tip. Every instrument undergoes a specialized polishing process to create an ultra-smooth internal lumen, ensuring that the high quality suction cannula provides a lifetime of surgical reliability and unmatched resistance to biological buildup during intensive fat transfer procedures.
Advanced Surgical Grade Construction
Constructed from high-tensile premium medical grade steel, this cannula offers exceptional durability and resistance to bending under vacuum pressure. The Accelerator fat suction tool is engineered with a smooth, non-traumatic tip that provides superior tactile sensitivity, allowing the surgeon to navigate various tissue layers with ease. This professional-grade liposuction harvesting tool is treated with an electrochemical passivation process, ensuring it remains a corrosion-resistant staple among your liposuction instruments. The tapered shaft is specifically balanced for ergonomic manipulation, significantly reducing hand fatigue during long body sculpting sessions. As a key component of our fat grafting tools collection, it excels in minimizing tissue trauma while enhancing procedural speed.
Care and Maintenance
- Cleaning: Initiate ultrasonic cleaning immediately following surgery to remove cellular debris from the internal lumen and ports.
- Sterilization: Fully autoclavable. Standard cycle: 134°C (273°F) for a minimum of 3.5 minutes.
- Internal Flushing: Use a specialized cannula brush and enzymatic cleaner to maintain fluid instrument motion.
- Inspection: Regularly examine the suction ports for nicks and verify that the connection hub locks securely.
Select Your Hub Connection (Customizable)
We offer a wide range of handle and hub connections to fit your specific suction system or syringe preference:
- Super Fix Handles (Style A & B): Heavy-duty power handles designed for tubing connection. Provide excellent grip for large-volume liposuction.
- Super Luer Lock: A premium wide-bore connection for smoother fat flow into syringes.
- Standard Luer Lock: Available in Stainless Steel (for durability) or Anodized Aluminum (for a lightweight feel).
- Toomey Hub (60cc): Wide connection specifically designed for 60cc Toomey syringes.
- Threaded Fitting: Compatible with specific power-assisted handles.
People Also Ask
Q: What makes the Accelerator design different from a standard cannula?
A: The Accelerator features a specialized three-port distal tip that creates a larger vacuum field, allowing for faster fat removal compared to standard single-port designs.
Q: Can this fat suction cannula be used for fat grafting?
A: Yes, the ports are designed to harvest high-quality adipose tissue with high cell viability, making it excellent for subsequent fat transfer injections.
Q: What connections are available for this cannula?
A: Adas Instruments offers the Accelerator Cannula with Luer Lock, Threaded, and Power Assisted Liposuction (PAL) hubs to fit various surgical systems.
Technical Details
| Technical Attribute | Specification Data |
|---|---|
| Instrument Model | Accelerator Liposuction Cannula, Tri-Port Cannula |
| Surgical Application | Fat Suction, Body Contouring, Fat Grafting, Fat Harvesting Tool |
| Port Configuration | Three Side-Ports (Accelerated Flow) |
| Hub Types Available | Luer Lock, Threaded Hub, Super-Luer, PAL |
| Material Composition | Premium Medical Grade Stainless Steel |
| Diameter Range | 2.0mm to 5.0mm Options |
| Working Length | 15cm to 35cm (Customizable) |
| Finish Coating | High-Mirror Polish |
| Sterilization Method | Autoclave Safe (Up to 134°C) |
| Regulatory Compliance | ISO and CE Certified |
Related Surgical Instruments
Liposuction Products: Explore our variety of Mercedes Liposuction Cannula or the Basket Liposuction Cannula.
Recommended Pairing: Combine this tool with our Fat Injector Gun or the Adson Forceps for high-precision results.














Reviews
There are no reviews yet.