Sorensen Harvester Liposuction Cannula: Optimized for High-Yield Fat Transfer
The Sorensen Harvester Liposuction Cannula is an essential instrument for modern surgeons specializing in autologous fat grafting and high-definition body sculpting. This Sorensen Cannula is engineered with a series of small, precisely spaced ports along the distal tip, allowing for rapid aspiration of adipose tissue while maintaining cellular integrity. It is widely regarded as a premier Fat Harvesting Instrument because it balances aggressive tissue collection with a design that minimizes trauma to the donor site stroma.
Utilizing a multi-port approach, the Sorensen design provides a 360-degree aspiration field, which is vital for achieving uniform results in the abdomen, thighs, and flanks. As a specialized Tissue Collection Cannula, it is designed to prevent the “clumping” of fat cells, ensuring a smooth, injectable consistency that is perfect for reinjection into the breasts, buttocks, or face. This high-efficiency Liposuction Harvester allows the surgeon to procure large volumes of viable fat in significantly less time than standard single-port models.
Precision Craftsmanship & Material Durability
Each Sorensen Harvester is crafted from the finest Medical-Grade Stainless Steel, ensuring it can withstand the high-torque environments of aggressive liposculpture. The internal lumen is micro-polished to eliminate any microscopic burrs that could damage delicate adipose cells, making it a truly high quality suction cannula. This professional-grade instrument is treated with a specialized passivation layer to ensure it remains rust-free throughout its clinical life. The ergonomic hub design provides superior tactile feedback, minimizing tissue trauma by allowing the surgeon to feel subtle changes in tissue resistance, which ultimately enhances procedural speed and patient safety.
Quality and Finishing
The Sorensen Harvester features a unique hybrid finish where the distal tip is satin-treated for glare reduction while the shaft is mirror-polished for effortless gliding. This meticulous hand-finishing process ensures that every port edge is perfectly smooth, preventing unintended tissue snagging or skin irregularities. This dedication to craftsmanship ensures that the cannula remains easy to decontaminate and stays resistant to the harsh chemicals used in modern sterilization protocols.
Care and Maintenance
- Internal Flushing: Use a high-pressure water jet and enzymatic cleaner to clear all ports immediately after harvesting.
- Port Brushing: Utilize a soft-bristle cannula brush to clear any trapped fibrous tissue from the multi-port openings.
- Sterilization: Fully autoclavable. Recommended cycle: 134°C (273°F) for 4 minutes.
- Hub Inspection: Ensure the O-ring or Luer connection is airtight to prevent vacuum loss during the procedure.
Select Your Hub Connection (Customizable)
We provide multiple hub configurations to ensure compatibility with your existing surgical equipment:
- Super Fix Handles (Style A & B): Ergonomic power handles designed for direct tubing connection and high-volume suction.
- Super Luer Lock: A specialized wide-bore connection that fits all syringe types, including Toomey and Luer Lock.
- Standard Luer Lock: Available in lightweight Anodized Aluminum or heavy-duty Stainless Steel.
- Toomey Hub (60cc): Designed for seamless attachment to 60cc Toomey syringes for manual extraction.
- Threaded Fitting: Compatible with various power-assisted handles and universal suction systems.
People Also Ask
Q: Why is the Sorensen harvester preferred for fat transfer?
A: The multi-port design allows for the collection of smaller, more uniform fat parcels which are highly viable and easier to reinject through fine needles.
Q: Is the Sorensen cannula more aggressive than a Mercedes cannula?
A: It is considered more efficient for harvesting because of the increased number of ports, but it is less aggressive on the tissue compared to larger, single-port designs.
Q: Can I use this cannula for standard liposuction without grafting?
A: Yes, it is an excellent tool for volume reduction, though its primary engineering focus is the preservation of fat for grafting purposes.
Technical Details
| Technical Attribute | Specification Data |
|---|---|
| Instrument Name | Sorensen Harvester Liposuction Cannula |
| Primary Use | High-Yield Fat Harvesting & Grafting |
| Port Configuration | Multi-Port (Helical or Linear Distribution) |
| Material | Surgical Grade Stainless Steel / German Grade |
| Diameter Options | 2.5mm, 3.0mm, 3.5mm, 4.0mm |
| Standard Lengths | 15cm, 20cm, 25cm, 30cm |
| Hub Compatibility | Luer Lock, Toomey, Power Fix, Threaded |
| Finishing | Satin Tip / Mirror Shaft Polish |
| Autoclave Safe | Yes (Up to 134°C) |
| Certifications | CE, ISO 13485, FDA-Ready |
Related Surgical Instruments
Liposuction Products: View our Mercedes Liposuction Cannula or the Kotzur 9 Holes Liposuction Cannula.
Recommended Pairing: Enhance your fat grafting with the Fat Injector Gun or our specialty Spatula Liposuction Cannula.















Reviews
There are no reviews yet.