What a V dissector cannula is
This is the fork tipped pattern in its plainest form. In our photograph the end of the tube splits into two short prongs with a V between them, a shallower notch than on our Toledo listings, and a single long port opens on the shaft just behind it.
Google AI Mode, read on 18 November 2026, describes the V dissector liposuction cannula, often listed as a Toledo V dissector, as an instrument with a fork shaped or V notched tip designed to break through dense, fibrous tissue and scar adhesions during liposuction and fat grafting. It says the port behind the notch suctions fat while the adhesions are released, and it names revision liposuction, the male chest, the upper back and flanks, facial contouring and the chin and neck, and equalizing uneven contours.
Gemini, read the same day, lists it as a fork tip V dissector cannula and sets it against a spatula. Plainly put, it is a fork tip liposuction cannula, which is how our own listing photograph is titled.
Key design features
A fork with a shallow notch
The V in our photograph is shallower than the notch on our Toledo patterns. Fibrous bands still ride into it and are released as the cannula moves forward, and the prongs push softer tissue aside.
One long port
A single long port opens just behind the fork. It takes fat from the plane the notch has just opened, or lets fat out into it when the cannula is used to make tunnels for grafting.
Seven ways to finish the back end
The order form offers seven ways to finish the back end: a super fix handle in style A or style B, an aluminum Luer lock, a steel Luer lock, a super Luer lock, a Toomey hub, or a threaded fitting. The Luer locks screw onto a syringe or a Luer handle. The Toomey hub takes a 60 cc Toomey syringe for harvesting or grafting by hand, and the super fix handles make the cannula one piece for a suction line. The hub sets the price: 22 dollars with the aluminum or steel Luer lock, 32 with the super Luer lock or the threaded fitting, 37 with the Toomey hub, and 45 or 55 with a super fix handle.
The hub decides the lengths
Our form keeps two size lists. With a Luer lock, the Toomey hub or the threaded fitting the 2 mm comes in 15 and 18 cm and the 4 mm in 20 to 35 cm. With a super fix handle the 3 mm comes in 15 to 35 cm and the 4 mm in 15 to 30 cm.
Which size to order
Every size below was read off our own order form on 18 November 2026. The size does not change the price; only the hub does. Pick the hub first, because it decides which lengths the form shows.
| Diameter | Lengths with a Luer, Toomey or threaded hub | Lengths with a super fix handle |
|---|---|---|
| 2 mm | 15 cm, 18 cm | 15 cm |
| 2.4 mm | 15 cm, 20 cm | 25 cm |
| 3 mm | 15 cm, 20 cm, 25 cm, 30 cm | 15 cm, 20 cm, 25 cm, 30 cm, 35 cm |
| 4 mm | 20 cm, 25 cm, 30 cm, 35 cm | 15 cm, 20 cm, 25 cm, 30 cm |
| 5 mm | 25 cm, 30 cm, 35 cm | 25 cm, 30 cm, 35 cm |
Where it is used
The first two columns come from the AI Mode answer and from Gemini, both read on 18 November 2026. They describe the pattern in general, not our measurements. The last column is our own guide to our sizes.
| Use | What the answers say it is for | Where our sizes fit |
|---|---|---|
| Revision liposuction | Scarred tissue from earlier surgery | 3 and 4 mm, 20 to 30 cm |
| Male chest | Firm, fibrous tissue | 3 and 4 mm, 15 to 25 cm |
| Upper back and flanks | Dense fat bound by septa | 4 and 5 mm, 25 to 35 cm |
| Chin and neck | Submental liposuction with a shorter, thinner shaft | 2 and 2.4 mm, 15 to 20 cm |
| Equalizing | Smoothing uneven contours and making graft tunnels | 2.4 and 3 mm, 15 to 25 cm |
What it is for, and what it is not for
The V dissector releases as it aspirates. The table names the jobs where another cannula of ours suits better.
| Job | Use the V dissector? | What to use instead or beside it |
|---|---|---|
| Breaking through fibrous tissue and adhesions | Yes | This is the job it is made for |
| A deeper notch | Beside it | The Toledo V dissector |
| Two ports behind the fork | Beside it | The Toledo V dissector double port |
| Separating planes with a flat tip | Beside it | A spatula cannula |
| A motor driven handpiece | Not this listing | Our power assisted cannulas, which carry their own hub |
How it compares with the rest of the dissector and spatula family
Five patterns make up this family on our site. The second column is read off each listing’s own photograph, and the last off each product’s order form, on 18 November 2026.
| Pattern | What the tip carries, from our own photograph | What that is for | On our order form |
|---|---|---|---|
| Toledo V dissector | a fork of two prongs with a V notch, one long port behind it | releasing fibrous bands while it aspirates | 2 to 5 mm, 15 to 35 cm, 7 hub styles |
| Toledo V dissector, double port | the same fork and V notch, with two long ports in a line | the same release with more open area behind it | 2 to 5 mm, 15 to 35 cm, 7 hub styles |
| V dissector, fork tip (this page) | a fork with a shallower V notch, one long port behind it | release and aspiration with a gentler notch | 2 to 5 mm, 15 to 35 cm, 7 hub styles |
| Spatula, dual port | a flattened, rounded spatula tip, two long ports in a line | separating planes and drawing fat from one side | 2 to 5 mm, 15 to 35 cm, 7 hub styles |
| Spatula, single port | a flattened, rounded spatula tip, one long port behind it | controlled work in small areas such as the neck | 2 to 5 mm, 15 to 35 cm, 7 hub styles |
Materials and finish
Every V dissector cannula we make is formed from high quality medical grade stainless steel. The steel itself is made to a German specification. We do not publish a grade number.
The fork and its notch are formed from the end of the tube itself, and the port is cut through the wall behind it. Look at the notch before each case: a burred or opened V no longer releases cleanly. On the aluminum Luer lock the hub is aluminum, and on the steel Luer lock it is steel. The hub changes how the cannula connects and nothing about the tip.
Caring for it
Flush the V dissector cannula as soon as it comes out of use, before fat sets in the lumen. Clear the V notch with a fine brush first, then the port from the outside, then push a brush through the full length of the lumen. Look through the tube against a light to be sure it is clear. Dry it, steam sterilize it on the normal instrument cycle, and store it straight.
Ordering and wholesale
The V dissector cannula is made by Adas Instruments in our own workshop and sold direct, which is why the price sits where it does against the catalog houses. Order one for a single tray, or in quantity for a hospital list or a distributor line. We do OEM work under your own brand and your own item numbers. Send us a sample and we will hold a run to your pattern rather than ours. Stock items ship from our own workshop. Backorder items take 10 to 12 working days to make. Every instrument carries a three year replacement warranty against manufacturing defects. Production is controlled under an ISO 13485 quality management system.
Frequently asked questions
What is a V dissector cannula used for?
It is used to break through dense, fibrous tissue and scar adhesions while it aspirates. The AI Mode answer we read names revision liposuction, the male chest, the upper back, flanks, chin and neck, and making tunnels for grafting. Which cases it suits is the surgeon’s call.
Is a V dissector cannula the same as a Toledo cannula?
The names overlap, and AI Mode says the V dissector is often listed as a Toledo V dissector. On our listings this fork has a shallower notch than the two Toledo patterns, and one port behind it.
What size V dissector cannula should I order?
That depends on the area and the surgeon. We make it from 2 to 5 mm and from 15 to 35 cm, and the size table above shows which lengths come with which hub. The 2 and 2.4 mm suit the chin and neck.
What is a liposuction cannula?
It is a hollow steel tube with one or more ports near its end. Connected to suction, a syringe or a pump, it draws fat in through the ports as the surgeon moves it back and forth. A fork tip adds a notch that releases fibrous bands as it goes.
How is it different from a spatula cannula?
A spatula ends in a flat, rounded blade that separates tissue planes without cutting. The V dissector ends in a fork whose notch releases fibrous bands, so it is the one to reach for where the tissue is bound by scar or septa.
Related products and categories
Three more patterns from the dissector and spatula family: spatula dual port cannula, spatula liposuction cannula and Toledo V dissector cannula. The whole range is in aspiration cannulas, and the handles, adapters and sets that go with it are under liposuction cannulas and accessories.












Reviews
There are no reviews yet.