What a mirrored accelerator liposuction cannula is
Start with the accelerator: two slots on the sides near the tip and one oval port between them, a triangle of three. Now copy that triangle and set the copy behind the first one, facing it. That is the mirrored accelerator. Our photograph shows a pair of side slots, then the oval port, then a second pair of side slots, five openings along the working end where the plain accelerator has three.
Google AI Mode, read on 18 November 2026, describes the mirrored accelerator cannula as an aggressive, multi port liposuction instrument for high volume fat extraction and for fat harvesting. It sets it against the standard three hole accelerator and counts five vents in a mirrored triangular pattern along the far end of the shaft. That is the same count our photograph shows.
The pattern is also listed as a dual sided accelerator cannula, and Gemini, read the same day, gives that alias too. Gemini also lists it as a mirrored tri-port cannula. All three names point at the doubled triangle. Because five ports open along a longer stretch of the tube, the pattern is made only in the body sizes, 3 to 5 mm and 25 to 35 cm.
Key design features
Five ports along the shaft
Count them in our photograph: two side slots near the tip, the oval port, and two more side slots behind it. A five port liposuction cannula opens more of its wall to the fat than a three port one of the same size, and that is the reason to choose it for heavier work on the body.
The triangle, mirrored
The second pair of slots faces the first across the oval port, so the layout reads the same from either end of the working section. Each pass of the cannula carries both groups of ports through the tunnel, one after the other.
Seven ways to finish the back end
The order form offers seven ways to finish the back end: a super fix handle in style A or style B, an aluminum Luer lock, a steel Luer lock, a super Luer lock, a Toomey hub, or a threaded fitting. The Luer locks screw onto a syringe or a Luer handle. The Toomey hub takes a 60 cc Toomey syringe for harvesting by hand, and the super fix handles make the cannula one piece for a suction line. The hub sets the price: 22 dollars with the aluminum or steel Luer lock, 32 with the super Luer lock or the threaded fitting, 37 with the Toomey hub, and 45 or 55 with a super fix handle.
Body sizes only
The order form offers 3, 4 and 5 mm, in 25, 30 and 35 cm. There is no 2 mm and nothing under 25 cm, because five ports need room on the tube. The two size lists differ a little by hub: the 3 mm comes in 35 cm only with a super fix handle, and the 4 mm in 35 cm only with the other hubs.
Which size to order
Every size below was read off our own order form on 18 November 2026. The size does not change the price; only the hub does. Pick the hub first, because it decides which lengths the form shows.
| Diameter | Lengths with a Luer, Toomey or threaded hub | Lengths with a super fix handle |
|---|---|---|
| 3 mm | 25 cm, 30 cm | 25 cm, 30 cm, 35 cm |
| 4 mm | 25 cm, 30 cm, 35 cm | 25 cm, 30 cm |
| 5 mm | 25 cm, 30 cm, 35 cm | 25 cm, 30 cm, 35 cm |
Where it is used
The first two columns come from the AI Mode answer and from Gemini, both read on 18 November 2026. They describe the pattern in general, not our measurements. The last column is our own guide to the sizes we make.
| Use | What the answers say it is for | Where our sizes fit |
|---|---|---|
| High volume debulking | Fast removal in dense or fibrous areas | 4 and 5 mm, 30 to 35 cm |
| Fat harvesting and grafting | Collecting fat for transfer | 3 and 4 mm, on a Toomey hub or a Luer lock syringe |
| Abdomen and waist | Named by Gemini among the areas it reaches | 4 and 5 mm, 25 to 35 cm |
| Lateral thighs and back | Named by Gemini, fibrous layers in several directions | 4 and 5 mm, 30 to 35 cm |
| Revision liposuction | Named by Gemini for a second operation | 3 and 4 mm, 25 to 30 cm |
What it is for, and what it is not for
The mirrored accelerator is a heavy working cannula. The table names the jobs where another cannula of ours suits better.
| Job | Use the mirrored accelerator? | What to use instead or beside it |
|---|---|---|
| Heavier debulking on the body | Yes | This is the job it is made for |
| Small areas such as the face or neck | No | The accelerator in 2 or 2.4 mm, 15 to 20 cm |
| Shaping close under the skin | Not its job | A spiral port pattern such as the candy cane superficial |
| Infusing tumescent fluid | No | An infiltration cannula from our tumescent range |
| A motor driven handpiece | Not this listing | Our power assisted cannulas, which carry their own hub |
How it compares with the rest of the spiral and accelerator family
Six patterns make up this family on our site. The second column is read off each listing’s own photograph, and the last off each product’s order form, on 18 November 2026.
| Pattern | What the tip carries, from our own photograph | What that is for | On our order form |
|---|---|---|---|
| Candy cane superficial | slanted ports set round the shaft on a spiral, behind a closed tip | shaping close under the skin, and harvesting | 3 to 7 mm, 20 to 45 cm, 7 hub styles |
| Candy cane | three slanted ports, two on top and a smaller one underneath between them | harvesting and general aspiration | no size or hub choice on the listing, so tell us both when you order |
| Helix 3 port | three ports cut across the shaft, each turned further round the tube | ports that face several ways along one stretch of shaft | 3 to 5 mm, 25 to 35 cm, 7 hub styles |
| Carraway harvester | a slot behind the tip, an oval port, then a slot on the underside | taking fat for grafting | 2 to 5 mm, 15 to 35 cm, 7 hub styles; tri port or six ports chosen first |
| Accelerator | two side slots near a pointed tip and one oval port behind them | debulking and contouring in larger areas | 2 to 5 mm, 15 to 35 cm, 7 hub styles |
| Mirrored accelerator (this page) | the accelerator triangle repeated: side slots, an oval port, side slots again | more open area along the shaft for heavier work | 3 to 5 mm, 25 to 35 cm, 7 hub styles |
Materials and finish
Every mirrored accelerator cannula we make is formed from high quality medical grade stainless steel. The steel itself is made to a German specification. We do not publish a grade number.
All five ports are cut through the wall of the tube, and their edges are what fat passes over on the way in. On the aluminum Luer lock the hub is aluminum, and on the steel Luer lock it is steel. The hub changes how the cannula connects and nothing about the tip.
Caring for it
Flush the mirrored accelerator liposuction cannula as soon as it comes out of use. Five ports means five places for tissue to lodge, so push a brush through the full length of the lumen and then work each port from the outside. Look through the tube against a light to be sure it is clear. Dry it, steam sterilize it on the normal instrument cycle, and store it flat in a tray long enough for a 35 cm shaft.
Ordering and wholesale
The mirrored accelerator liposuction cannula is made by Adas Instruments in our own workshop and sold direct, which is why the price sits where it does against the catalog houses. Order one for a single tray, or in quantity for a hospital list or a distributor line. We do OEM work under your own brand and your own item numbers. Send us a sample and we will hold a run to your pattern rather than ours. Stock items ship from our own workshop. Backorder items take 10 to 12 working days to make. Every instrument carries a three year replacement warranty against manufacturing defects. Production is controlled under an ISO 13485 quality management system.
Frequently asked questions
What is a mirrored accelerator liposuction cannula used for?
It is used for high volume fat removal and for fat harvesting. The AI Mode answer we read names dense or fibrous areas during body contouring, and Gemini adds the abdomen, waist, lateral thighs and back. Which areas it goes into is the surgeon’s call.
How many ports does a mirrored accelerator liposuction cannula have?
Ours has five. Our photograph shows a pair of side slots near the tip, an oval port behind them and a second pair of side slots behind that. The AI Mode answer counts five vents for the pattern as well.
What size mirrored accelerator liposuction cannula should I order?
That depends on the area and the surgeon. We make it in 3, 4 and 5 mm, in 25, 30 and 35 cm, and the size table above shows which lengths come with which hub. The larger, longer sizes suit the abdomen and the thighs.
Is a dual sided accelerator cannula the same thing?
Yes. Dual sided accelerator cannula is another name for the mirrored pattern, and Gemini gives it as an alias too. Both describe the same five port tip, with the accelerator triangle repeated along the shaft.
How is it different from the accelerator?
The accelerator has one triangle of three ports close to the tip and comes from 2 to 5 mm, 15 to 35 cm. The mirrored version adds a second pair of side slots, five ports in all, and is made only in the body sizes from 3 to 5 mm.
Related products and categories
Three more patterns from the accelerator and spiral family: candy cane superficial liposuction cannula, candy cane liposuction cannula and helix 3 port cannula. The whole range is in aspiration cannulas, and the handles, adapters and sets that go with it are under liposuction cannulas and accessories.











Reviews
There are no reviews yet.