What a spatula liposuction cannula with a fix handle is
The spatula is the flat tipped pattern. In our photograph the end of the tube is pressed out into a broad, rounded blade, wider than the tube is round, and a single slot port opens on top just behind it. Seen from the side the tip is thin; seen from above it is wide.
Google AI Mode, read on 22 November 2026, describes a spatula liposuction cannula with a fixed handle as a reusable aspiration instrument with a flattened, blunt tip permanently bonded to the grip for direct suction tubing connection. The flattened tip, it says, separates tissue planes smoothly while spreading force over a wider surface. It describes single port, dual port and three hole versions, the single port being the least aggressive, for delicate contouring. Ours here is the single port spatula cannula with a fixed handle.
Gemini, asked the same day, calls it a flat single port spatula cannula and sets it against the spatula dual port: one opening for delicate superficial work in the neck and arms. The plain spatula cannula covers it too.
Key design features
A flat blade of a tip
The broad, thin tip slides between layers instead of pushing a round point through them. That is what AI Mode means by separating planes smoothly, and it is why the spatula is reached for close under the skin and in revision work, where the tissue is already disturbed.
One port, the gentle setting
A single slot behind the blade keeps the open area small, which is why AI Mode calls the single port spatula the least aggressive of its kind. For more open area on the same blade, our spatula dual port carries two.
The handle
Ours has no thumb vent, unlike some AI Mode mentions. The handle in our photograph is dark, almost black, with a grip of raised rings in the middle and a smooth collar at the front where the steel tube goes in. The tube is fixed in it for good: there is no thread to tighten and no hub to work loose. At the back the handle ends in a stepped, barbed nozzle that takes the suction tubing directly.
Standard or coated
The order form offers every size two ways. Standard, with no coating, is 55 dollars; with a titanium nitride coating it is 65. Titanium nitride is a hard, gold colored ceramic layer on the surface of the tube, and our own earlier listing gives it as the way to extend the working life of the tube. Both versions carry the same blade and port in the same 22 sizes.
Which size to order
Every size below was read off our own order form on 22 November 2026: 22 sizes in all. The size does not change the price; the coating does. Each one comes standard at 55 dollars or titanium nitride coated at 65, and every size was in stock that day.
| Diameter | Lengths on the order form | Price |
|---|---|---|
| 1.5 mm | 15 cm, 20 cm | 55 dollars, or 65 coated |
| 2 mm | 15 cm, 20 cm, 25 cm | 55 dollars, or 65 coated |
| 2.5 mm | 15 cm, 20 cm, 25 cm, 30 cm | 55 dollars, or 65 coated |
| 3 mm | 20 cm, 25 cm, 30 cm | 55 dollars, or 65 coated |
| 4 mm | 25 cm, 30 cm, 35 cm | 55 dollars, or 65 coated |
| 5 mm | 25 cm, 30 cm, 35 cm, 40 cm | 55 dollars, or 65 coated |
| 6 mm | 35 cm, 40 cm, 45 cm | 55 dollars, or 65 coated |
Where it is used
The first two columns come from the AI Mode answer and from Gemini, both read on 22 November 2026. They describe the pattern in general, not our measurements. The last column is our own guide to our sizes.
| Use | What the answers say | Where our sizes fit |
|---|---|---|
| Delicate contouring | Single port, least aggressive, in AI Mode | 1.5 and 2 mm, 15 to 25 cm |
| Superficial fat, neck and arms | Named by Gemini | 2 and 2.5 mm, 15 to 30 cm |
| Separating tissue planes | A flat tip spreads its force, in AI Mode | 2.5 and 3 mm |
| Larger areas, one port | The same blade on a wider tube | 4 to 6 mm, 25 to 45 cm |
What it is for, and what it is not for
The spatula is for smooth separation and gentle suction. The table names the jobs where another cannula of ours suits better.
| Job | Use the spatula? | What to use instead or beside it |
|---|---|---|
| Delicate, superficial work with a flat tip | Yes | This is the job it is made for |
| The same blade with more open area | Beside it | The spatula dual port liposuction cannula |
| Dividing fibrous bands | Beside it | The Toledo V dissector liposuction cannula |
| Bulk removal of soft fat | Not its job | The double Mercedes fix handle cannula |
| A syringe or a separate handle | Not this listing | The detachable spatula cannula in our aspiration range |
How it compares with the rest of the dissector and spatula family
Four one piece patterns make up this family. The second column is read off each listing’s own photograph, and the last off each product’s order form, on 22 November 2026.
| Pattern | What the tip carries, from our own photograph | What that is for | On our order form |
|---|---|---|---|
| Toledo V dissector | a forked V tip with one oval port behind the fork | releasing fibrous bands while aspirating | 2 to 6 mm, 15 to 40 cm, 18 sizes |
| V dissector | a tapered shaft ending in a V notch, one oval port behind it | opening fibrous planes with a shallower notch | 2 to 6 mm, 15 to 40 cm, 18 sizes |
| Spatula (this page) | a flattened spatula tip with one slot port behind it | separating planes, delicate superficial work | 1.5 to 6 mm, 15 to 45 cm, 22 sizes |
| Spatula dual port | a flattened spatula tip with two slot ports in a row | the spatula with more open area | 1.5 to 6 mm, 15 to 45 cm, 22 sizes |
Materials and finish
The spatula liposuction cannula is made in two parts, as our own record says. The tube is formed from high quality medical grade stainless steel, and the steel itself is made to a German specification. The aluminum handle is finished dark and holds the tube for good. We do not publish an alloy or a grade number for either part.
The blade is formed from the end of the tube itself, so the tip and the tube are one piece of steel. Check the edges of the blade before each case for nicks. On the coated version the gold colored titanium nitride layer covers the tube; the handle is the same on both.
Caring for it
Flush the spatula liposuction cannula through the handle nozzle as soon as it comes out of use, before fat sets in the lumen. The flattened end narrows the lumen just behind the tip, so push a fine brush through the port and past the blade as well as down the tube. Look through the tube against a light to be sure it is clear, dry it, and steam sterilize it whole on the normal instrument cycle, because the handle and tube do not come apart. Store it flat so the tube stays straight.
Ordering and wholesale
The spatula liposuction cannula with a fix handle is made by Adas Instruments in our own workshop and sold direct, which is why the price sits where it does against the catalog houses. Order one for a single tray, or in quantity for a hospital list or a distributor line. We do OEM work under your own brand and your own item numbers. Send us a sample and we will hold a run to your pattern rather than ours. Stock items ship from our own workshop. Backorder items take 10 to 12 working days to make. Every instrument carries a three year replacement warranty against manufacturing defects. Production is controlled under an ISO 13485 quality management system.
Frequently asked questions
What is a spatula liposuction cannula with a fix handle used for?
It is used for delicate, superficial liposuction and for separating tissue planes, with a flat tip that spreads its force and one port that keeps the suction gentle. Gemini names the neck and arms. Which cases suit it is the surgeon’s call.
Why is the tip of a spatula cannula flat?
So it slides between layers rather than pushing through them. AI Mode describes the flattened tip as separating planes smoothly while spreading force over a wider surface, which is the reason the pattern is used close under the skin.
What sizes does the spatula liposuction cannula with a fix handle come in?
Twenty two sizes on our form, the widest choice in the range: 1.5 mm in 15 and 20 cm, 2 and 2.5 mm in 15 to 30 cm, 3 mm in 20 to 30 cm, and 4 to 6 mm in 25 to 45 cm. Each is 55 dollars standard or 65 dollars coated.
How is the spatula liposuction cannula with a fix handle different from the dual port?
The dual port carries a second slot behind the same flat tip, for more open area. This one has a single slot, the gentler of the two. Both share the same 22 sizes, handle and prices.
What is a liposuction cannula?
It is a hollow steel tube with a blunt tip and one or more ports near the end, moved under the skin while suction draws fat in. This one has a flattened tip and a single port, and its tube is fixed in a handle that takes the tubing directly.
Related products and categories
Three more one piece cannulas from the dissector and spatula family: spatula dual port liposuction cannula, Toledo V dissector liposuction cannula and V dissector liposuction cannula. The whole range is in fix handle liposuction cannulas, and the detachable cannulas, handles and accessories are under liposuction cannulas and accessories.












Reviews
There are no reviews yet.