What a Blugerman II liposuction cannula is
The Blugerman II spreads its openings a long way down the shaft. In our photograph small round holes run in two staggered rows along a long stretch of the shaft, and part way along them sits a single elongated slot. Holes continue on the far side of the slot as well, so the working section is long and evenly pierced.
Google AI Mode, read on 18 November 2026, describes the Blugerman liposuction cannula as an instrument for high volume fat harvesting, debulking and lipo shifting, with multiple sharp edged round apertures along the far end of the shaft. It separates the two patterns: the Blugerman I for finer harvesting and smooth contouring, the Blugerman II with a larger port pattern for heavier extraction and deeper debulking.
Buyers search for both patterns as a Blugerman cannula, and Gemini, read the same day, lists this one as a Blugerman 2 liposuction cannula. It places the work in fibrous fat of the back, the flanks, the male chest and the upper abdomen.
Key design features
Ports along a long stretch
The round holes in our photograph start close to the tip and carry on well back along the shaft. Spread out like that, they share the suction over a long working section, which is what lets the pattern take fat in larger amounts.
One slot among the holes
Part way along the rows there is a single elongated slot, larger than any of the round holes. It opens more of the tube at one point, and the round holes before and after it take the fat on either side.
Seven ways to finish the back end
The order form offers seven ways to finish the back end: a super fix handle in style A or style B, an aluminum Luer lock, a steel Luer lock, a super Luer lock, a Toomey hub, or a threaded fitting. The Luer locks screw onto a syringe or a Luer handle. The Toomey hub takes a 60 cc Toomey syringe, and the super fix handles make the cannula one piece for a suction line. The hub sets the price: 22 dollars with the aluminum or steel Luer lock, 32 with the super Luer lock or the threaded fitting, 37 with the Toomey hub, and 45 or 55 with a super fix handle.
The hub decides the lengths
Our form starts at 2.4 mm. With a Luer lock, the Toomey hub or the threaded fitting the 5 mm comes in 30 and 35 cm; with a super fix handle it comes in 15, 25 and 30 cm, and the 4 mm in 15 cm too. Pick the hub first and the form shows only what it can make.
Which size to order
Every size below was read off our own order form on 18 November 2026. The size does not change the price; only the hub does. Pick the hub first, because it decides which lengths the form shows.
| Diameter | Lengths with a Luer, Toomey or threaded hub | Lengths with a super fix handle |
|---|---|---|
| 2.4 mm | 15 cm, 25 cm | 25 cm |
| 3 mm | 15 cm, 25 cm, 30 cm | 15 cm, 25 cm, 30 cm |
| 4 mm | 25 cm, 30 cm, 35 cm | 15 cm, 25 cm, 30 cm |
| 5 mm | 30 cm, 35 cm | 15 cm, 25 cm, 30 cm |
Where it is used
The first two columns come from the AI Mode answer and from Gemini, both read on 18 November 2026. They describe the pattern in general, not our measurements. The last column is our own guide to our sizes.
| Use | What the answers say it is for | Where our sizes fit |
|---|---|---|
| High volume harvesting | Taking larger amounts of fat | 4 and 5 mm, 25 to 35 cm, on a Toomey hub |
| Debulking | Deep removal on the body | 4 and 5 mm, 25 to 35 cm |
| Lipo shifting | Moving fat from one area into another | 3 and 4 mm, 25 to 30 cm |
| Back and flanks | Named by Gemini, fibrous fat | 4 and 5 mm, 30 to 35 cm |
| Male chest | Named by Gemini, fibrous fat | 3 and 4 mm, 15 to 25 cm |
What it is for, and what it is not for
The Blugerman II is the heavier of the pair. The table names the jobs where another cannula of ours suits better.
| Job | Use the Blugerman II? | What to use instead or beside it |
|---|---|---|
| Harvesting and debulking over a long stretch | Yes | This is the job it is made for |
| Finer harvesting and smooth contouring | Not its job | The Blugerman I |
| Very fine fat for the face | No | The Sattler tip or the Sorensen harvester |
| Putting the fat back in | No | A fat injection cannula from our fat transfer range |
| A motor driven handpiece | Not this listing | Our power assisted cannulas, which carry their own hub |
How it compares with the rest of the harvester family
Six harvesters make up this family on our site. The second column is read off each listing’s own photograph, and the last off each product’s order form, on 18 November 2026.
| Pattern | What the tip carries, from our own photograph | What that is for | On our order form |
|---|---|---|---|
| Large volume harvester | long oval ports in two staggered rows along the end | taking larger volumes of fat for grafting | 2 to 5 mm, 15 to 35 cm, 7 hub styles |
| Sattler tip | many small round holes in rows behind a rounded tip | fine fat for small grafts | no size or hub choice on the listing, so tell us both when you order |
| Sorensen harvester | small slanted holes in two staggered rows | fine, even fat for transfer | 2 to 5 mm, 15 to 35 cm, 5 hub styles |
| Harvester, raised edge ports | small ports, each with a raised, pointed edge | harvesting through fibrous fat | 2 to 5 mm, 15 to 35 cm, 7 hub styles |
| Blugerman II (this page) | small round holes along a long stretch, with one slot part way along | harvesting and debulking over a longer stretch | 2.4 to 5 mm, 15 to 35 cm, 7 hub styles |
| Blugerman I | small round holes near the tip, then one slot behind them | harvesting from a shorter stretch of shaft | no size or hub choice on the listing, so tell us both when you order |
Materials and finish
Every Blugerman II cannula we make is formed from high quality medical grade stainless steel. The steel itself is made to a German specification. We do not publish a grade number.
The round ports and the slot are cut through the wall of the tube, and their edges are what fat passes over on the way in. On the aluminum Luer lock the hub is aluminum, and on the steel Luer lock it is steel. The hub changes how the cannula connects and nothing about the tip.
Caring for it
Flush the Blugerman II liposuction cannula as soon as it comes out of use, before fat sets in the lumen. A long run of small holes takes time to clear, so flush the rows from the outside with a syringe, then push a brush through the full length of the lumen and past the slot. Look through the tube against a light to be sure it is clear. Dry it, steam sterilize it on the normal instrument cycle, and store it straight.
Ordering and wholesale
The Blugerman II liposuction cannula is made by Adas Instruments in our own workshop and sold direct, which is why the price sits where it does against the catalog houses. Order one for a single tray, or in quantity for a hospital list or a distributor line. We do OEM work under your own brand and your own item numbers. Send us a sample and we will hold a run to your pattern rather than ours. Stock items ship from our own workshop. Backorder items take 10 to 12 working days to make. Every instrument carries a three year replacement warranty against manufacturing defects. Production is controlled under an ISO 13485 quality management system.
Frequently asked questions
What is a Blugerman II liposuction cannula used for?
It is used for fat harvesting, debulking and lipo shifting. The AI Mode answer we read describes the II as the pattern for heavier extraction and deeper debulking, and Gemini names the back, flanks, male chest and upper abdomen. Which areas it goes into is the surgeon’s call.
What is the difference between the Blugerman I and the Blugerman II liposuction cannula?
On our two listings, the Blugerman I carries its round holes close to the tip with the slot behind them, and has no size choice. The Blugerman II runs its holes along a longer stretch, with the slot part way along, and comes from 2.4 to 5 mm.
What size Blugerman II liposuction cannula should I order?
That depends on the area and the surgeon. We make it from 2.4 to 5 mm and from 15 to 35 cm, and the size table above shows which lengths come with which hub. The 4 and 5 mm in the longer lengths suit the body.
What are the different types of liposuction cannulas?
They are told apart by the tip and the ports. A one hole draws from a single point, a Mercedes from a ring of three, a basket or a grater roughens fibrous fat, and a multi hole harvester like this one spreads many ports along the shaft. Our range is in the aspiration cannulas category.
Is a Blugerman cannula reusable?
Yes. Ours is made from high quality medical grade stainless steel and goes through the normal steam cycle. Flush and brush the rows of holes before it dries, and check the slot and the holes against a light before the next case.
Related products and categories
Three more patterns from the harvester family: Blugerman I liposuction cannula, large volume harvester cannula and Sattler tip liposuction cannula. The whole range is in aspiration cannulas, and the handles, adapters and sets that go with it are under liposuction cannulas and accessories.












Reviews
There are no reviews yet.