What a suction coagulator is
Bleeding in a narrow field fills it faster than a surgeon can see through it. With a separate suction tube and cautery, the hands change instruments every few seconds and the bleeding point is lost each time. A suction coagulator clears the blood and coagulates the vessel with the same tip, so the point stays in view while it is sealed.
Google AI Mode, read on 23 November 2026, describes a suction coagulator as a specialized surgical instrument that combines fluid aspiration and electrosurgical tissue coagulation in a single handheld device, allowing surgeons to clear blood and fluids while stopping bleeding without switching instruments. It names 8, 10 and 12 Fr sizes on insulated shafts, and says most standard models are monopolar.
Buyers ask for a coagulator in short, a suction coagulator ent by the field, a monopolar suction coagulator by the current, or suction cautery in plain words. All of them describe this one instrument.
AI Mode gives ENT work first: tonsillectomy, adenoidectomy and sinus surgery, where pooling blood fills narrow spaces. It adds general and open surgery for diffuse oozing and fluid in deep cavities. In breast surgery the same tool clears and seals small bleeders deep in a pocket where a pencil and a separate suction would crowd each other.
Key design features
Suction and coagulation together
The tube carries suction and current at once. The surgeon draws the blood away to see the vessel, then applies current through the same tip, as AI Mode describes. The two jobs can also be used one at a time.
An insulated tube
The photographs of our listing show a black insulated tube on a black handle, with only the tip bare. The insulation keeps current at the tip, so the wall of the field along the tube is not touched by it.
Sizes and tip forms on our listing
Our listing names 6, 8, 10 and 12 Fr and a curved or straight tip. They are not separate price lines, so tell us the size and tip you need when you order and we will confirm them. The smaller sizes suit a narrow field; the larger ones clear blood faster. A curved tip reaches around a structure to a bleeding point behind it; a straight tip suits a point in direct view.
With or without a cable
The price changes only with the cable. Without a cable it is 28.50 dollars, for an operating room that already has one; with a reusable monopolar cable it is 67 dollars, the grey cable shown in our second photograph.
Which one to order
Every line below is read off our own listing on 23 November 2026. Both builds are in stock.
| Build | What comes with it | Price |
|---|---|---|
| Without cable | the suction coagulator alone | 28.50 dollars |
| With cable | the suction coagulator and a reusable monopolar cable | 67 dollars |
| Size | 6, 8, 10 or 12 Fr, confirmed on order | same price |
| Tip | curved or straight, confirmed on order | same price |
Where it is used
The first two columns come from the AI Mode answer read on 23 November 2026. The last column is our own guide.
| Job | What AI Mode says | Which size |
|---|---|---|
| Tonsillectomy and adenoidectomy | ENT, named first | 8 or 10 Fr |
| Sinus surgery | Pooling blood in narrow spaces | 6 or 8 Fr |
| Diffuse oozing in open surgery | General and open surgery | 10 or 12 Fr |
| Fluid in deep cavities | Evacuating fluid | 12 Fr |
| Small bleeders in a breast pocket | Suction and coagulation together | 10 Fr, curved |
What it is for, and what it is not for
This is a monopolar suction coagulator. The table names the jobs where another item of ours suits better.
| Job | Use the suction coagulator? | What to use instead or beside it |
|---|---|---|
| Clearing blood and coagulating at one point | Yes | This is the job it is made for |
| Grasping a single vessel before coagulating | Beside it | The McIndoe monopolar forceps |
| Endoscopic breast pocket dissection | No | The Emory endoscopic electrosurgical dissector |
| Suction only, no current | No | A Frazier or Adson suction tube |
| Bipolar coagulation | No | A bipolar forceps on our bipolar cable |
How it compares with the rest of the set
Four electrosurgery items make up this set. Every cell is read off each listing’s own record and photograph on 23 November 2026.
| Item | What it is, from our record and photograph | Builds on our listing | Job | Price |
|---|---|---|---|---|
| McIndoe monopolar forceps | insulated thumb forceps, bare 2.0 mm tips | one listing, in stock | grasping and coagulating small vessels | 24.50 dollars |
| Emory endoscopic electrosurgical dissector | handle, cable and four insulated spatula tip shafts | one listing, made to order | pocket dissection with coagulation and suction | 160 dollars |
| Suction coagulator (this page) | insulated suction tube on a handle | with or without a reusable monopolar cable | suction and coagulation in one instrument | 28.50 or 67 dollars |
| Bipolar cable for forceps, American 2 pin | grey cable, two pin plugs at each end | one 3 meter listing, in stock | linking American style bipolar forceps to the generator | 38.50 dollars |
Materials and finish
Every suction coagulator tube we make is formed from high quality medical grade stainless steel, and the steel itself is made to a German specification. The tube carries an insulating coat, left off the working tip. We do not publish a grade number.
The four items in this set work with one of two kinds of current, and the difference decides what each is for. In monopolar work the current leaves the tip, passes through the patient and returns to the generator through a pad on the skin. The McIndoe forceps, the Emory dissector and the suction coagulator are monopolar. In bipolar work the current passes only between the two tips of a bipolar forceps, so no pad is needed, and the cable in this set carries that current from the generator to the forceps.
All four depend on their insulation. On the monopolar items it confines the current to the bare working end; on the cable it keeps the two conductors apart and the current inside. That is why every care paragraph in this set asks for a look along the insulation before the next case.
Each of the four connects to the generator through a plug, and generator sockets differ between makes. Before the first case with a new generator, check the plug against the socket: the monopolar items take the monopolar socket, and the bipolar cable takes the bipolar socket. We confirm the match on request if you tell us the generator model when you order.
Caring for it
Wipe the suction coagulator clean as soon as it comes out of use, before blood and char dry on it. Flush the tube with water straight after use, and clear it with a cleaning wire, before blood sets inside it. Look along the insulation under a good light before every case: a crack, a nick or a worn patch lets current leave where it should not, and an item with damaged insulation goes out of use until it is replaced. Dry it fully, steam sterilize it on the normal instrument cycle, and store it where nothing sharp or heavy lies on it.
Ordering and wholesale
Each suction coagulator is made by Adas Instruments in our own workshop and sold direct, which is why the price sits where it does against the catalog houses. Order one for a single tray, or in quantity for a hospital list or a distributor line. We do OEM work under your own brand and your own item numbers. Send us a sample and we will hold a run to your pattern rather than ours. Stock items ship from our own workshop. Backorder items take 10 to 12 working days to make. Every instrument carries a three year replacement warranty against manufacturing defects. Production is controlled under an ISO 13485 quality management system.
Frequently asked questions
What is a suction coagulator used for?
It is used to clear blood and fluid from the field and coagulate bleeding with the same tip, without changing instruments, as AI Mode describes. ENT work comes first, with general, open and breast surgery beside it. The case is the surgeon’s call.
What sizes does this suction coagulator come in?
Our listing names 6, 8, 10 and 12 Fr, each with a curved or straight tip. They are not separate price lines, so state the size and tip when you order and we will confirm them in writing before the instrument ships.
Does the suction coagulator come with a cable?
Only if you choose it. The coagulator alone is 28.50 dollars; with a reusable monopolar cable it is 67 dollars. If your operating room already has a matching monopolar cable, the cheaper build is all you need.
Is this suction coagulator monopolar or bipolar?
Monopolar. Current leaves the tip and returns through a pad on the patient. AI Mode notes that most standard suction coagulators are monopolar, with bipolar versions kept for delicate neuro and micro work, which this listing does not cover.
What is a coagulator in surgery?
A coagulator is an instrument that applies electrosurgical current to stop bleeding by sealing tissue. This one adds suction through the same tube. The McIndoe forceps and the Emory dissector in this set are coagulating instruments of other shapes.
Related products and categories
The three other electrosurgery items in this set: Bipolar cable for forceps, American 2 pin, McIndoe monopolar forceps and Emory endoscopic electrosurgical dissector. The whole breast range is in breast surgery instruments, and every monopolar and bipolar item we make is listed under electrosurgery instruments.







Reviews
There are no reviews yet.