What the MacCollum Dingman breast dissector is
The Maccollum dingman breast dissector is a hand instrument used to open and mobilize a pocket in breast surgery. Surgeons also call it a MacCollum Dingman dissector, a Dingman breast dissector or simply a breast surgery dissector. It is made by Adas Instruments in high quality medical grade stainless steel, and it is reusable and fully autoclavable.
It is 43 cm long with a 38 mm wide blade, which is the widest blade in this range, and that width is what lets it sweep a pocket open in a few passes instead of a dozen.
The work a breast dissector does is always the same in principle. A pocket has to be opened along a plane that already exists, without cutting through it and without tearing the tissue on either side. A blunt end pushed along that plane separates it and leaves the small vessels intact, which is why the field stays dry. The width of the blade and the stiffness of the shaft decide which pattern a surgeon picks up.
Key design features of the MacCollum Dingman breast dissector
- Overall length 43 cm, about 17 in
- Blade 38 mm wide, the broadest in this range
- Broad blunt end that opens a plane in fewer passes
- Stiff shaft that holds its line at full extension
- Flat handle that shows the blade angle by feel
- High quality medical grade stainless steel, reusable and autoclavable
The handle is flat and knurled rather than round. A flat handle tells you which way the blade is facing when the working end is deep in a pocket and out of sight, and the knurling holds when a glove is wet. The shaft runs into the blade with no step, so there is no shoulder to catch on the edge of an incision and nothing for protein to sit in after a case.
MacCollum Dingman dissector sizes and build options
Every size below is a size we actually ship. Imperial figures are given beside the metric because United States buyers search in inches.
| Overall length | Imperial | Blade width | Blade form | Item code |
|---|---|---|---|---|
| 43 cm | 17 in | 38 mm | Wide, blunt | AN-03.17 |
Nothing is listed above that we do not hold. If a build you need is not in the table, ask, because a pattern like this is often made to order for an OEM run and a change of length or blade width is a tooling change rather than a new instrument.
Uses of the MacCollum Dingman breast dissector by specialty
The MacCollum Dingman breast dissector appears on the same trays across these specialties because the job is the same one each time, opening a plane bluntly and holding the pocket where the surgeon meant it to stop.
| Specialty | Procedure |
|---|---|
| Breast augmentation | A broad sweep once the pocket is open |
| Breast reconstruction | Lifting pectoralis off the chest wall |
| Plastic surgery | Blunt soft tissue dissection over a wide field |
| Revision breast surgery | Blunt separation along an established capsule |
| Mastopexy | Release at the inframammary fold |
| Oncoplastic breast surgery | Wide blunt mobilization of a flap |
| Gender affirming chest surgery | Broad blunt dissection of the chest wall plane |
The specialty name and the procedure name are both worth knowing when you order, because catalogues file this pattern under whichever of the two the buyer used. An operating room manager searches by procedure and a purchasing office searches by specialty, and they are looking for the same instrument.
Tissue planes the MacCollum Dingman breast dissector works in
A breast dissector handles no suture and no needle. What decides the choice of pattern is the plane it has to open, how far the working end has to travel to reach it, and how much room there is to move once it is there.
| Tissue plane | How this pattern works it |
|---|---|
| Subglandular pocket | Broad blade sweeps the plane in few passes |
| Submuscular pocket | Lifts pectoralis off the chest wall |
| Inframammary fold | Blunt release at the lower edge |
| Lateral pocket border | Wide blade spreads the load where the pocket must stop |
| Capsule in a revision case | Blunt separation along an established plane |
Force is the part nobody writes down. A subglandular plane in a young patient opens with almost nothing, while a capsule in a revision case needs a firm push and a stiff shaft behind it. Match the blade to the plane and the instrument does the work instead of your wrist.
How the MacCollum Dingman breast dissector compares with other patterns
These four sit next to each other on a breast tray and they are not interchangeable.
| Pattern | What is different | When you reach for it |
|---|---|---|
| MacCollum Dingman breast dissector | 43 cm, 38 mm wide blade | A broad sweep once the pocket is open |
| MacCollum Dingman submammary dissector | 30 cm, 20 mm blade | A narrower blade in a tighter pocket |
| Agris Dingman breast dissector | 35 cm and 40 cm, transaxillary | Reaching the far edge from the axilla |
| Penn breast dissector | 32 cm, straight wide blade | A straight sweep at a shorter reach |
Surgeons who use this pattern usually also hold the MacCollum Dingman submammary dissector, the Agris Dingman breast dissector and the Penn breast dissector. The closest relative in the range is the MacCollum Dingman submammary dissector.
If you are building a breast tray from scratch, the usual answer is two dissectors rather than one. Something long for the far edge of the pocket and something shorter with more feel at the tip covers almost every case.
Materials and finish
The instrument is made in high quality medical grade stainless steel. The steel itself is made to a German specification. The blade is flat ground and satin finished, which cuts glare under the lights in an operating room and keeps the working end readable against wet tissue. There is no coating to chip and nothing on the shaft to trap protein.
Stainless steel is chosen here for a reason that has nothing to do with appearance. A long shafted dissector is pushed hard at full extension, and a shaft that is too soft will take a set and stay bent, which throws the blade out of the plane on the next pass. A shaft that is too hard will crack at the neck instead. The grade used sits between the two.
Maccollum dingman breast dissector care and sterilization
Rinse the instrument in cool water straight after use so blood does not dry on the blade. Clean it with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, then dry it completely. Steam autoclave at 134 degrees Celsius. Lay it flat in the tray with nothing resting across the shaft, because a long shaft that has been loaded sideways in a crowded tray is the one that comes back bent.
Look at the working end against the light before every case. A blunt end should be smooth with no flat spot and no nick, and the shaft should still be straight when you sight down it. A dissector with a nick on the end is what tears a pocket two cases later, and it costs nothing to check.
Ordering and wholesale
This pattern is supplied by Adas Instruments to hospitals, surgical distributors and OEM buyers, in single units and in bulk. The item code is AN-03.17 and it is printed in the size table above so a procurement search finds it. Backorder items dispatch in 10 to 12 working days. Every instrument carries a three year replacement against manufacturing defects.
For wholesale and OEM orders, instruments ship unpackaged in bulk or individually poly bagged, and laser marking with a distributor code or a hospital asset number is available on the shaft. Tell us the quantity and the marking you need and the quotation comes back with the lead time for that run rather than a stock figure.
Production is controlled under an ISO 13485 quality management system. The instrument is CE marked.
Frequently asked questions
What is a MacCollum Dingman breast dissector used for?
It dissects and mobilizes breast tissue during augmentation, reconstruction and mastopexy. The 38 mm blade is the reason to pick it: a wide blade opens a pocket in fewer passes, and fewer passes means less bleeding.
How wide is the blade?
38 mm, on a 43 cm shaft. That is the broadest blade in this range, so it is chosen once the pocket is open rather than for starting a tight plane.
When would you choose the narrower submammary build instead?
When the pocket is tight or the incision is small. A 38 mm blade needs room to turn, and in a submammary pocket the 20 mm build works the same plane without fighting it.
Is a breast surgery dissector the same as a breast elevator?
They overlap. A dissector opens a plane over distance and an elevator lifts one layer off another. This pattern is catalogued as a dissector because the pocket, not the layer, is what it is built for.
How do you clean and sterilize it?
Rinse in cool water straight after use, clean with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, dry fully, then steam autoclave at 134 degrees Celsius.
Related products and categories
Surgeons who work with the MacCollum Dingman breast dissector usually compare it against the MacCollum Dingman submammary dissector, the Agris Dingman breast dissector and the Penn breast dissector. The whole family sits in dissectors and elevators, and this pattern is also listed under breast surgery instruments.






Reviews
There are no reviews yet.