What the McKenty nasal septum elevator is
The McKenty nasal septum elevator is a hand instrument used to separate soft tissue from cartilage and bone inside the nose. Surgeons also call it a McKenty septum elevator, a McKenty elevator or a McKenty septal elevator. It is made by Adas Instruments in high quality medical grade stainless steel, and it is reusable and fully autoclavable.
It is made in two tip widths, 4 mm and 5 mm, on a short 15 cm shaft, so the working end stays close to the hand in a narrow nasal cavity.
The work an elevator does is always the same in principle. A layer of soft tissue is stuck to the cartilage or bone under it, and it has to come off in one sheet without a hole in it. Get that right and the rest of the operation has a dry field and a flap that will lie back down. Get it wrong and you are repairing a tear for the next ten minutes. That is why the shape of the working end, the stiffness of the blade and the length of the shaft are the three things that decide which pattern a surgeon picks up.
Key design features of the McKenty nasal septum elevator
- Tip options 4 mm and 5 mm, chosen at the point of order
- Short 15 cm shaft keeps the tip close to the hand for control
- Blunt working blade that separates the flap rather than cutting it
- Suited to a narrow nasal cavity and to pediatric septal work
- Flat knurled handle for a pencil grip
- High quality medical grade stainless steel, reusable and autoclavable
The handle is flat and knurled rather than round. A flat handle tells you where the blade is facing without looking at it, and the knurling holds when a glove is wet. The shaft runs straight into the blade with no step, so there is no shoulder to catch on the rim of a nostril and nothing for protein to sit in after a case.
McKenty elevator sizes and build options
Every size below is a size we actually ship. Imperial figures are given beside the metric because United States buyers search in inches.
| Overall length | Imperial | Tip or blade | Build | Item code |
|---|---|---|---|---|
| 15 cm | 6 in | 4 mm | Narrow tip option | ADR-157.04 |
| 15 cm | 6 in | 5 mm | Wider tip option | ADR-157.04 |
Nothing is listed above that we do not hold. If a length you need is not in the table, ask, because a pattern like this is often made to order for an OEM run and a different length is a tooling change rather than a new instrument.
Uses of the McKenty nasal septum elevator by specialty
The McKenty nasal septum elevator appears on the same trays across these specialties because the job is the same one each time, lifting a tissue plane cleanly off what lies under it.
| Specialty | Procedure |
|---|---|
| ENT surgery | Septoplasty in a narrow nasal cavity |
| Plastic surgery | Rhinoplasty exposure |
| Facial plastic surgery | Nasal valve repair |
| Pediatric ENT | Pediatric septal work |
| Sinus surgery | Turbinate mucosal release |
| Oral and maxillofacial surgery | Short reach mucoperiosteal elevation |
| Trauma surgery | Fine blunt septal release |
The specialty name and the procedure name are both worth knowing when you order, because catalogues file this pattern under whichever of the two the buyer used. An operating room manager searches by procedure and a purchasing office searches by specialty, and they are looking for the same instrument.
Tissue planes the McKenty nasal septum elevator works in
An elevator handles no suture and no needle. What decides the choice of pattern is the plane it has to open and how much force that plane takes.
| Tissue plane | How this pattern works it |
|---|---|
| Mucoperichondrial flap | Blunt blade, separation in a narrow field |
| Mucoperiosteum over the bony septum | Blunt blade, short reach |
| Septal cartilage surface | Exposure before harvest |
| Inferior turbinate mucosa | Careful blunt release |
| Nasal valve area | Fine 4 mm tip for a tight corner |
Force is the part nobody writes down. Perichondrium on young cartilage lifts with almost nothing. Mucoperiosteum on the bony septum needs a firm push and a stiff blade behind it. Scarred tissue in a revision case needs more again, and that is the point at which a light blade starts to flex and the plane is lost. Match the blade to the plane and the instrument does the work instead of your wrist.
How the McKenty nasal septum elevator compares with other patterns
These four sit next to each other on a nasal tray and they are not interchangeable.
| Pattern | What is different | When you reach for it |
|---|---|---|
| McKenty nasal septum elevator | 15 cm, tip options 4 mm and 5 mm | Narrow fields and short reach |
| McKenty nasal septum elevator double ended | 22 cm, a blade at each end | Longer reach and two working ends |
| Freer septum elevator | 18 cm, one sharp one blunt end | Starting and raising the flap |
| Cottle septum elevator | 23 cm, spatulate both ends | Posterior septal access |
Surgeons who use this pattern usually also hold the Howarth septum elevator, the Freer septum elevator and the Cottle septum elevator. The closest relative in the range is the McKenty nasal septum elevator double ended.
If you are building a nasal tray from scratch, the usual answer is two elevators rather than one. Something light for cartilage and something stiffer for bone covers almost every case, and the third and fourth patterns get added for the particular operations a unit does often.
Materials and finish
The instrument is made in high quality medical grade stainless steel. The steel itself is made to a German specification. The blade is flat ground and satin finished, which cuts glare under the lights in an operating room and keeps the working end readable against wet tissue. There is no coating to chip and nothing on the shaft to trap protein.
Stainless steel is chosen here for a reason that has nothing to do with appearance. An elevator is levered, and a levered instrument that is too hard will crack at the neck while one that is too soft will take a set and stay bent. The grade used for this pattern sits between the two, which is why the blade can be thinned at the working end without losing the shaft.
McKenty nasal septum elevator care and sterilization
Rinse the instrument in cool water straight after use so blood does not dry on the blade. Clean it with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, then dry it completely. Steam autoclave at 134 degrees Celsius. Lay it in the tray so the blades do not rest against other instruments, because a bruised edge on an elevator is what tears a flap.
Look at the working end against the light before every case. A blunt end should be smooth with no flat spot and no nick, and a sharp end should still take a clean line. An elevator that has been dropped on a tiled floor is the one that buttonholes a flap two cases later, and it costs nothing to check.
Ordering and wholesale
This pattern is supplied by Adas Instruments to hospitals, surgical distributors and OEM buyers, in single units and in bulk. The item code is ADR-157.04 and it is printed in the size table above so a procurement search finds it. Backorder items dispatch in 10 to 12 working days. Every instrument carries a three year replacement against manufacturing defects.
For wholesale and OEM orders, instruments ship unpackaged in bulk or individually poly bagged, and laser marking with a distributor code or a hospital asset number is available on the shaft. Tell us the quantity and the marking you need and the quotation comes back with the lead time for that run rather than a stock figure.
Production is controlled under an ISO 13485 quality management system.
Frequently asked questions
What is a McKenty septum elevator used for?
The McKenty nasal septum elevator raises the mucoperichondrial flap off the nasal septum in septoplasty and rhinoplasty. Its short 15 cm shaft keeps the working tip close to the hand, which helps in a narrow nasal cavity.
What tip widths does the McKenty elevator come in?
This pattern is made in two tip widths, 4 mm and 5 mm. The 4 mm tip suits a tight corner such as the nasal valve area and the 5 mm tip covers broader elevation.
What is the difference between the McKenty and the McKenty double ended elevator?
This pattern is 15 cm with one working blade in a choice of 4 mm or 5 mm. The double ended McKenty is 22 cm and carries a blade at each end, so it gives longer reach and two working ends on one shaft.
Is the McKenty elevator suitable for pediatric septal surgery?
The short shaft and the 4 mm tip make it a reasonable choice in a small nasal cavity, and the blade is blunt so the thinner flap is separated rather than cut.
How do you clean a McKenty septal elevator?
Rinse in cool water immediately after use, clean with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water and dry fully before steam autoclaving at 134 degrees Celsius.
Related products and categories
Surgeons who work with the McKenty nasal septum elevator usually compare it against the Howarth septum elevator, the Freer septum elevator and the Cottle septum elevator. The whole family sits in dissectors and elevators, and this pattern is also listed under rhinoplasty instruments.





Reviews
There are no reviews yet.