What the McKenty nasal septum elevator double ended is
The McKenty nasal septum elevator double ended is a hand instrument used to separate soft tissue from cartilage and bone inside the nose. Surgeons also call it a double ended McKenty elevator, a McKenty double ended septum elevator or a McKenty double ended nasal elevator. It is made by Adas Instruments in high quality medical grade stainless steel, and it is reusable and fully autoclavable.
It carries a working blade at each side of a 22 cm shaft in tip widths of 4 mm and 5 mm, so one instrument covers a narrow corner and a broad sweep.
The work an elevator does is always the same in principle. A layer of soft tissue is stuck to the cartilage or bone under it, and it has to come off in one sheet without a hole in it. Get that right and the rest of the operation has a dry field and a flap that will lie back down. Get it wrong and you are repairing a tear for the next ten minutes. That is why the shape of the working end, the stiffness of the blade and the length of the shaft are the three things that decide which pattern a surgeon picks up.
Key design features of the McKenty nasal septum elevator double ended
- Double ended, a working blade at each side of the shaft
- Tip options 4 mm and 5 mm
- Overall length 22 cm, about 8.75 in, for posterior septal reach
- Blunt blades that separate the flap rather than cutting it
- Flat knurled handle for a pencil grip
- High quality medical grade stainless steel, reusable and autoclavable
The handle is flat and knurled rather than round. A flat handle tells you where the blade is facing without looking at it, and the knurling holds when a glove is wet. The shaft runs straight into the blade with no step, so there is no shoulder to catch on the rim of a nostril and nothing for protein to sit in after a case.
McKenty elevator sizes and build options
Every size below is a size we actually ship. Imperial figures are given beside the metric because United States buyers search in inches.
| Overall length | Imperial | Tip or blade | Build | Item code |
|---|---|---|---|---|
| 22 cm | 8.75 in | 4 mm and 5 mm | Double ended | ADR-152.22 |
Nothing is listed above that we do not hold. If a length you need is not in the table, ask, because a pattern like this is often made to order for an OEM run and a different length is a tooling change rather than a new instrument.
Uses of the McKenty nasal septum elevator double ended by specialty
The McKenty nasal septum elevator double ended appears on the same trays across these specialties because the job is the same one each time, lifting a tissue plane cleanly off what lies under it.
| Specialty | Procedure |
|---|---|
| ENT surgery | Septoplasty with posterior reach |
| Plastic surgery | Rhinoplasty exposure |
| Facial plastic surgery | Nasal valve repair with the narrow end |
| Sinus surgery | Turbinate mucosal release |
| Oral and maxillofacial surgery | Mucoperiosteal elevation |
| Pediatric ENT | Narrow end in a small cavity |
| Trauma surgery | Blunt septal release |
The specialty name and the procedure name are both worth knowing when you order, because catalogues file this pattern under whichever of the two the buyer used. An operating room manager searches by procedure and a purchasing office searches by specialty, and they are looking for the same instrument.
Tissue planes the McKenty nasal septum elevator double ended works in
An elevator handles no suture and no needle. What decides the choice of pattern is the plane it has to open and how much force that plane takes.
| Tissue plane | How this pattern works it |
|---|---|
| Mucoperichondrial flap | Wider end, broad separation |
| Mucoperiosteum over the bony septum | Wider end, firm elevation |
| Posterior septum | Long 22 cm shaft reaches it |
| Nasal valve area | Narrow 4 mm end in a tight corner |
| Inferior turbinate mucosa | Careful blunt release |
Force is the part nobody writes down. Perichondrium on young cartilage lifts with almost nothing. Mucoperiosteum on the bony septum needs a firm push and a stiff blade behind it. Scarred tissue in a revision case needs more again, and that is the point at which a light blade starts to flex and the plane is lost. Match the blade to the plane and the instrument does the work instead of your wrist.
How the McKenty nasal septum elevator double ended compares with other patterns
These four sit next to each other on a nasal tray and they are not interchangeable.
| Pattern | What is different | When you reach for it |
|---|---|---|
| McKenty nasal septum elevator double ended | 22 cm, a blade at each end | Longer reach and two working ends |
| McKenty nasal septum elevator | 15 cm, one blade, 4 mm or 5 mm | Short reach in a narrow field |
| Masing septum elevator | 22 cm, 5 mm blades both ends | Broad deep elevation |
| Cottle septum elevator | 23 cm, spatulate both ends | Posterior access with no sharp edge |
Surgeons who use this pattern usually also hold the Gorney septum suction elevator, the Freer septum elevator and the Cottle septum elevator. The closest relative in the range is the McKenty nasal septum elevator.
If you are building a nasal tray from scratch, the usual answer is two elevators rather than one. Something light for cartilage and something stiffer for bone covers almost every case, and the third and fourth patterns get added for the particular operations a unit does often.
Materials and finish
The instrument is made in high quality medical grade stainless steel. The steel itself is made to a German specification. The blade is flat ground and satin finished, which cuts glare under the lights in an operating room and keeps the working end readable against wet tissue. There is no coating to chip and nothing on the shaft to trap protein.
Stainless steel is chosen here for a reason that has nothing to do with appearance. An elevator is levered, and a levered instrument that is too hard will crack at the neck while one that is too soft will take a set and stay bent. The grade used for this pattern sits between the two, which is why the blade can be thinned at the working end without losing the shaft.
McKenty nasal septum elevator double ended care and sterilization
Rinse the instrument in cool water straight after use so blood does not dry on the blade. Clean it with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, then dry it completely. Steam autoclave at 134 degrees Celsius. Lay it in the tray so the blades do not rest against other instruments, because a bruised edge on an elevator is what tears a flap.
Look at the working end against the light before every case. A blunt end should be smooth with no flat spot and no nick, and a sharp end should still take a clean line. An elevator that has been dropped on a tiled floor is the one that buttonholes a flap two cases later, and it costs nothing to check.
Ordering and wholesale
This pattern is supplied by Adas Instruments to hospitals, surgical distributors and OEM buyers, in single units and in bulk. The item code is ADR-152.22 and it is printed in the size table above so a procurement search finds it. Backorder items dispatch in 10 to 12 working days. Every instrument carries a three year replacement against manufacturing defects.
For wholesale and OEM orders, instruments ship unpackaged in bulk or individually poly bagged, and laser marking with a distributor code or a hospital asset number is available on the shaft. Tell us the quantity and the marking you need and the quotation comes back with the lead time for that run rather than a stock figure.
Production is controlled under an ISO 13485 quality management system.
Frequently asked questions
What is a double ended McKenty elevator used for?
It raises the mucoperichondrial flap off the nasal septum in septoplasty and rhinoplasty, with a working blade at each side of a 22 cm shaft. The two tip widths mean one instrument covers both a tight corner and a broad sweep.
What is the difference between this and the 15 cm McKenty elevator?
This build is 22 cm with a blade at each end. The other McKenty pattern is 15 cm with a single working blade in a choice of 4 mm or 5 mm, and it is the one to pick when the field is narrow and the reach is short.
What tip widths does the double ended McKenty have?
The tips are 4 mm and 5 mm, so the narrow end works the nasal valve area and the wider end raises a broad flap.
How long is the double ended McKenty elevator?
This pattern is 22 cm overall, about 8.75 in, which is long enough to reach the posterior septum.
How do you sterilize a McKenty double ended elevator?
Rinse in cool water after use, clean with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, dry fully, then steam autoclave at 134 degrees Celsius.
Related products and categories
Surgeons who work with the McKenty nasal septum elevator double ended usually compare it against the Gorney septum suction elevator, the Freer septum elevator and the Cottle septum elevator. The whole family sits in dissectors and elevators, and this pattern is also listed under rhinoplasty instruments.




Reviews