What the MacCollum Dingman submammary dissector is
The Maccollum dingman submammary dissector is a hand instrument used to open and mobilize a pocket in breast surgery. Surgeons also call it a submammary dissector, a MacCollum Dingman dissector or a breast surgery dissector. It is made by Adas Instruments in high quality medical grade stainless steel, and it is reusable and fully autoclavable.
It is 30 cm long with a 20 mm blade, which is the narrower of the two MacCollum Dingman builds, and it is the one that suits a submammary pocket where a wider blade has nowhere to turn.
The work a breast dissector does is always the same in principle. A pocket has to be opened along a plane that already exists, without cutting through it and without tearing the tissue on either side. A blunt end pushed along that plane separates it and leaves the small vessels intact, which is why the field stays dry. The width of the blade and the stiffness of the shaft decide which pattern a surgeon picks up.
Key design features of the MacCollum Dingman submammary dissector
- Overall length 30 cm, about 11.75 in
- Blade 20 mm wide, narrower than the 38 mm build
- Suits a submammary pocket and a small incision
- Blunt end that separates a plane rather than dividing it
- Flat handle for a firm grip at a shorter reach
- High quality medical grade stainless steel, reusable and autoclavable
The handle is flat and knurled rather than round. A flat handle tells you which way the blade is facing when the working end is deep in a pocket and out of sight, and the knurling holds when a glove is wet. The shaft runs into the blade with no step, so there is no shoulder to catch on the edge of an incision and nothing for protein to sit in after a case.
MacCollum Dingman dissector sizes and build options
Every size below is a size we actually ship. Imperial figures are given beside the metric because United States buyers search in inches.
| Overall length | Imperial | Blade width | Blade form | Item code |
|---|---|---|---|---|
| 30 cm | 11.75 in | 20 mm | Wide, blunt | AN-04.11 |
Nothing is listed above that we do not hold. If a build you need is not in the table, ask, because a pattern like this is often made to order for an OEM run and a change of length or blade width is a tooling change rather than a new instrument.
Uses of the MacCollum Dingman submammary dissector by specialty
The MacCollum Dingman submammary dissector appears on the same trays across these specialties because the job is the same one each time, opening a plane bluntly and holding the pocket where the surgeon meant it to stop.
| Specialty | Procedure |
|---|---|
| Breast augmentation | Submammary pocket dissection through a small incision |
| Breast reconstruction | Blunt work in a tight pocket |
| Plastic surgery | Controlled blunt dissection in a narrow field |
| Revision breast surgery | Blunt separation where the pocket is already tight |
| Mastopexy | Release at the lower pole |
| Oncoplastic breast surgery | Mobilizing tissue in a confined space |
| Periareolar approach surgery | Reaching the pocket from a short incision |
The specialty name and the procedure name are both worth knowing when you order, because catalogues file this pattern under whichever of the two the buyer used. An operating room manager searches by procedure and a purchasing office searches by specialty, and they are looking for the same instrument.
Tissue planes the MacCollum Dingman submammary dissector works in
A breast dissector handles no suture and no needle. What decides the choice of pattern is the plane it has to open, how far the working end has to travel to reach it, and how much room there is to move once it is there.
| Tissue plane | How this pattern works it |
|---|---|
| Submammary pocket | Narrow blade turns where a wider one cannot |
| Subglandular plane | Blunt sweep off the chest wall |
| Inframammary fold | Release at the lower edge through a small incision |
| Medial pocket border | Controlled separation near the sternum |
| Capsule in a revision case | Blunt work along an established plane |
Force is the part nobody writes down. A subglandular plane in a young patient opens with almost nothing, while a capsule in a revision case needs a firm push and a stiff shaft behind it. Match the blade to the plane and the instrument does the work instead of your wrist.
How the MacCollum Dingman submammary dissector compares with other patterns
These four sit next to each other on a breast tray and they are not interchangeable.
| Pattern | What is different | When you reach for it |
|---|---|---|
| MacCollum Dingman submammary dissector | 30 cm, 20 mm blade | A tight pocket or a small incision |
| MacCollum Dingman breast dissector | 43 cm, 38 mm blade | A broad sweep once the pocket is open |
| Penn breast dissector | 32 cm, straight wide blade | A straight sweep at a similar reach |
| Wieslander breast dissector | Its own wide blade pattern | Held beside it on the same tray |
Surgeons who use this pattern usually also hold the MacCollum Dingman breast dissector, the Penn breast dissector and the Wieslander breast dissector. The closest relative in the range is the MacCollum Dingman breast dissector.
If you are building a breast tray from scratch, the usual answer is two dissectors rather than one. Something long for the far edge of the pocket and something shorter with more feel at the tip covers almost every case.
Materials and finish
The instrument is made in high quality medical grade stainless steel. The steel itself is made to a German specification. The blade is flat ground and satin finished, which cuts glare under the lights in an operating room and keeps the working end readable against wet tissue. There is no coating to chip and nothing on the shaft to trap protein.
Stainless steel is chosen here for a reason that has nothing to do with appearance. A long shafted dissector is pushed hard at full extension, and a shaft that is too soft will take a set and stay bent, which throws the blade out of the plane on the next pass. A shaft that is too hard will crack at the neck instead. The grade used sits between the two.
Maccollum dingman submammary dissector care and sterilization
Rinse the instrument in cool water straight after use so blood does not dry on the blade. Clean it with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, then dry it completely. Steam autoclave at 134 degrees Celsius. Lay it flat in the tray with nothing resting across the shaft, because a long shaft that has been loaded sideways in a crowded tray is the one that comes back bent.
Look at the working end against the light before every case. A blunt end should be smooth with no flat spot and no nick, and the shaft should still be straight when you sight down it. A dissector with a nick on the end is what tears a pocket two cases later, and it costs nothing to check.
Ordering and wholesale
This pattern is supplied by Adas Instruments to hospitals, surgical distributors and OEM buyers, in single units and in bulk. The item code is AN-04.11 and it is printed in the size table above so a procurement search finds it. Backorder items dispatch in 10 to 12 working days. Every instrument carries a three year replacement against manufacturing defects.
For wholesale and OEM orders, instruments ship unpackaged in bulk or individually poly bagged, and laser marking with a distributor code or a hospital asset number is available on the shaft. Tell us the quantity and the marking you need and the quotation comes back with the lead time for that run rather than a stock figure.
Production is controlled under an ISO 13485 quality management system. The instrument is CE marked.
Frequently asked questions
What is a submammary dissector used for?
It opens and mobilizes the pocket under the breast in augmentation and reconstruction. The narrow 20 mm blade is the point: in a submammary pocket a wide blade has nowhere to turn, and forcing it is how a plane gets torn.
How is it different from the 43 cm MacCollum Dingman?
Same family, different build. This one is 30 cm with a 20 mm blade for a tight pocket. The other is 43 cm with a 38 mm blade for a broad sweep. Units that do both kinds of case usually hold one of each.
Does the shorter length limit what it can reach?
Only at the far edge of a large pocket. For a submammary plane worked through an inframammary incision, 30 cm puts the hand where it can feel what the tip is doing.
Is it blunt?
Yes. A breast surgery dissector of this type separates and sweeps. Nothing on it is meant to cut.
How do you clean and sterilize a MacCollum Dingman dissector?
Rinse in cool water immediately after use, clean with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, dry fully, then steam autoclave at 134 degrees Celsius.
Related products and categories
Surgeons who work with the MacCollum Dingman submammary dissector usually compare it against the MacCollum Dingman breast dissector, the Penn breast dissector and the Wieslander breast dissector. The whole family sits in dissectors and elevators, and this pattern is also listed under breast surgery instruments.





Reviews