What the Reynolds transaxillary breast dissector is
The Reynolds transaxillary breast dissector is a hand instrument used to open and mobilize a pocket in breast surgery. Surgeons also call it a Reynolds breast dissector, a transaxillary breast dissector or a transaxillary pocket dissector. It is made by Adas Instruments in high quality medical grade stainless steel, and it is reusable and fully autoclavable.
The Reynolds is 39.4 cm long, printed in United States catalogues as 15.5 in, with a 38 mm blade on a straight shaft. That is the pattern: reach to work from the axilla, and blade enough to sweep a pocket open in few passes.
The work a breast dissector does is always the same in principle. A pocket has to be opened along a plane that already exists, without cutting through it and without tearing the tissue on either side. A blunt end pushed along that plane separates it and leaves the small vessels intact, which is why the field stays dry. The width of the blade, the shape of the shaft and how far the end has to travel decide which pattern a surgeon picks up.
Key design features of the Reynolds transaxillary breast dissector
- Overall length 39.4 cm, printed in United States catalogues as 15.5 in
- Blade 38 mm wide, the width the transaxillary approach is built around
- Straight shaft, so the pocket is worked from more than one direction
- Blunt working end that opens a plane instead of cutting it
- Flat handle that shows the blade angle by feel when the end is out of sight
- High quality medical grade stainless steel, reusable and autoclavable
The handle is flat and knurled rather than round. A flat handle tells you which way the blade is facing when the working end is deep in a pocket and out of sight, and the knurling holds when a glove is wet. The shaft runs into the blade with no step, so there is no shoulder to catch on the edge of an incision and nothing for protein to sit in after a case.
Reynolds dissector sizes and build options
Every size below is a size we actually ship. Imperial figures are given beside the metric because United States buyers search in inches.
| Overall length | Imperial | Blade width | Shaft | Item code |
|---|---|---|---|---|
| 39.4 cm | 15.5 in | 38 mm | Straight | AN-10.15 |
Nothing is listed above that we do not hold. If a build you need is not in the table, ask, because a change of length or blade width is a tooling change rather than a new instrument.
Uses of the Reynolds transaxillary breast dissector by specialty
The Reynolds transaxillary breast dissector appears on the same trays across these specialties because the job is the same one each time, opening a plane bluntly and holding the pocket where the surgeon meant it to stop.
| Specialty | Procedure |
|---|---|
| Breast augmentation | Opening the pocket through a transaxillary incision |
| Breast reconstruction | Mobilizing a submuscular pocket at reach |
| Plastic surgery | Blunt soft tissue dissection over the chest wall |
| Revision breast surgery | Blunt separation along an established capsule |
| Mastopexy | Release at the inframammary fold |
| Oncoplastic breast surgery | Wide blunt mobilization of a flap |
| Gender affirming chest surgery | Blunt pocket dissection |
The specialty name and the procedure name are both worth knowing when you order, because catalogues file this pattern under whichever of the two the buyer used. An operating room manager searches by procedure and a purchasing office searches by specialty, and they are looking for the same instrument.
Tissue planes the Reynolds transaxillary breast dissector works in
A breast dissector handles no suture and no needle. What decides the choice of pattern is the plane it has to open, how far the working end has to travel to reach it, and how much room there is to move once it is there.
| Tissue plane | How this pattern works it |
|---|---|
| Subglandular pocket | Wide blade sweeps the plane in few passes |
| Submuscular pocket | Lifts pectoralis off the chest wall at reach |
| Transaxillary tunnel | The straight Reynolds shaft carries the blade from the axilla to the pocket |
| Inframammary fold | Blunt release at the lower edge |
| Lateral pocket border | Wide blade spreads the load where the pocket must stop |
Force is the part nobody writes down. A subglandular plane in a young patient opens with almost nothing, while a capsule in a revision case needs a firm push and a stiff shaft behind it. Match the blade to the plane and the instrument does the work instead of your wrist.
How the Reynolds transaxillary breast dissector compares with other patterns
These four sit next to each other on a breast tray and they are not interchangeable.
| Pattern | What is different | When you reach for it |
|---|---|---|
| Reynolds transaxillary breast dissector | 15.5 in, straight shaft, 38 mm wide blade | A wide sweep at reach from an axillary incision |
| Jacobs transaxillary dissector | Curved shaft, narrower blade | The same approach where the plane curves and the space is tight |
| Agris Dingman breast dissector | 35 cm and 40 cm, handed left and right tips | Working the far edge with a handed tip |
| Wieslander breast dissector | 18.1 in, longer again | When even 15.5 in runs out |
Surgeons who use this pattern usually also hold the Agris Dingman breast dissector, the Jacobs transaxillary dissector and the Wieslander breast dissector. The closest relative in the range is the Jacobs transaxillary dissector.
If you are building a breast tray from scratch, the usual answer is two dissectors rather than one. Something long for the far edge of the pocket and something shorter with more feel at the tip covers almost every case.
Materials and finish
The instrument is made in high quality medical grade stainless steel. The steel itself is made to a German specification. The working face is ground and satin finished, which cuts glare under the lights in an operating room and keeps the end readable against wet tissue. There is no coating to chip and nothing on the shaft to trap protein.
Stainless steel is chosen here for a reason that has nothing to do with appearance. A long shafted dissector is pushed hard at full extension, and a shaft that is too soft will take a set and stay bent, which throws the blade out of the plane on the next pass. A shaft that is too hard will crack at the neck instead. The grade used sits between the two.
Reynolds transaxillary breast dissector care and sterilization
Rinse the instrument in cool water straight after use so blood does not dry on it. Clean it with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, then dry it completely. Steam autoclave at 134 degrees Celsius. Lay it flat in the tray with nothing resting across it, because an instrument loaded sideways in a crowded tray is the one that comes back out of true.
Look at the working end against the light before every case. A blunt end should be smooth with no flat spot and no nick, and the shaft should still be straight when you sight down it. A dissector with a nick on the end is what tears a pocket two cases later, and it costs nothing to check.
Ordering and wholesale
This pattern is supplied by Adas Instruments to hospitals, surgical distributors and OEM buyers, in single units and in bulk. The item code is AN-10.15 and it is printed in the size table above so a procurement search finds it. Backorder items dispatch in 10 to 12 working days. Every instrument carries a three year replacement against manufacturing defects.
For wholesale and OEM orders, instruments ship unpackaged in bulk or individually poly bagged, and laser marking with a distributor code or a hospital asset number is available. Tell us the quantity and the marking you need and the quotation comes back with the lead time for that run rather than a stock figure.
Production is controlled under an ISO 13485 quality management system. The instrument is CE marked.
Frequently asked questions
What is a Reynolds transaxillary breast dissector used for?
It opens and mobilizes the implant pocket in breast augmentation and reconstruction, working either subglandular or submuscular. It is chosen when the incision is in the axilla, because the working end has to travel from the armpit to the chest wall before it starts working.
Why is the Reynolds blade 38 mm wide?
Because a wide blade spreads the load. A narrow tip concentrates force at a point and can push through a plane instead of along it. At 38 mm the Reynolds sweeps a pocket open in a few passes and keeps the pressure off any one spot.
Straight shaft or curved, which should I choose?
Straight, which is what the Reynolds is, lets you come at the pocket from more than one direction and is the usual first choice. A curved shaft follows a specific contour and suits a tighter, more defined path.
How long is the Reynolds breast dissector?
39.4 cm overall, which United States catalogues print as 15.5 in. Distributors also list it as a Reynolds transaxillary pocket dissector.
How do you clean and sterilize a Reynolds dissector?
Rinse in cool water straight after use, clean with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, dry fully, then steam autoclave at 134 degrees Celsius. Lay the long shaft flat so nothing rests across it.
Related products and categories
Surgeons who work with the Reynolds transaxillary breast dissector usually compare it against the Agris Dingman breast dissector, the Jacobs transaxillary dissector and the Wieslander breast dissector. It sits beside the Mammostat breast elevator on the same tray. The whole family sits in dissectors and elevators, and this pattern is also listed under breast surgery instruments.