What the Spatulated blade breast dissector is
The Spatulated blade breast dissector is a hand instrument used to open and shape the implant pocket in breast surgery. Surgeons also call it a spatula breast dissector, a breast spatula or a dissection spatula. It is made by Adas Instruments in high quality medical grade stainless steel, and it is reusable and fully autoclavable.
The blade is a flat paddle, and flat is the point. A spatulated face meets the plane along its whole width, so every stroke separates the widest strip of tissue the instrument can manage rather than a narrow line down the middle.
The work a breast dissector does is always the same in principle. A pocket has to be opened along a plane that already exists, without cutting through it and without tearing the tissue on either side. A blunt end pushed along that plane separates it and leaves the small vessels intact, which is why the field stays dry. The width of the blade, the shape of the shaft and how far the end has to travel decide which pattern a surgeon picks up.
Key design features of the Spatulated blade breast dissector
- Flat spatulated blade that meets the plane across its whole width
- Insulated or non insulated shaft, chosen at order
- Two builds, 33 cm with a 22 cm working length and 42 cm with a 30 cm working length
- Blunt working end that separates a plane instead of cutting it
- Lifts pectoralis major without a sharp edge anywhere on the instrument
- High quality medical grade stainless steel, reusable and autoclavable
The handle is flat and knurled rather than round. A flat handle tells you which way the blade is facing when the working end is deep in a pocket and out of sight, and the knurling holds when a glove is wet. The shaft runs into the blade with no step, so there is no shoulder to catch on the edge of an incision and nothing for protein to sit in after a case.
Spatulated dissector sizes and build options
Every size below is a size we actually ship. Imperial figures are given beside the metric because United States buyers search in inches.
| Overall length | Imperial | Working length | Shaft |
|---|---|---|---|
| 33 cm | 13 in | 22 cm | Insulated or non insulated |
| 42 cm | 16.5 in | 30 cm | Insulated or non insulated |
Nothing is listed above that we do not hold. If a build you need is not in the table, ask, because a change of length or blade width is a tooling change rather than a new instrument.
Uses of the Spatulated blade breast dissector by specialty
The Spatulated blade breast dissector appears on the same trays across these specialties because the job is the same one each time, opening a plane bluntly and holding the pocket where the surgeon meant it to stop.
| Specialty | Procedure |
|---|---|
| Breast augmentation | Creating and shaping the implant pocket |
| Breast reconstruction | Lifting pectoralis major with a broad face |
| Plastic surgery | Blunt separation of connective tissue |
| Revision breast surgery | Blunt work along an established capsule |
| Mastopexy | Release at the lower pole |
| Oncoplastic breast surgery | Wide blunt mobilization of a flap |
| Gender affirming chest surgery | Broad blunt pocket dissection |
The specialty name and the procedure name are both worth knowing when you order, because catalogues file this pattern under whichever of the two the buyer used. They are looking for the same instrument.
Tissue planes the Spatulated blade breast dissector works in
A breast dissector handles no suture and no needle. What decides the choice of pattern is the plane it has to open, how far the working end has to travel to reach it, and how much room there is to move once it is there.
| Tissue plane | How this pattern works it |
|---|---|
| Subglandular pocket | Flat face separates the widest strip per stroke |
| Submuscular pocket | Lifts pectoralis major with no sharp edge involved |
| Connective tissue between planes | Broad face parts it instead of cutting it |
| Lateral pocket border | Spreads the load where the pocket must stop |
| Bleeding point deep in the pocket | The insulated build carries energy to the tip and nowhere else |
Force is the part nobody writes down. A subglandular plane in a young patient opens with almost nothing, while a capsule in a revision case needs a firm push and a stiff shaft behind it. Match the blade to the plane and the instrument does the work instead of your wrist.
How the Spatulated blade breast dissector compares with other patterns
These four sit next to each other on a breast tray and they are not interchangeable.
| Pattern | What is different | When you reach for it |
|---|---|---|
| Spatulated blade breast dissector | Flat paddle blade, insulated option | A broad flat sweep in an open plane |
| Oval spatulated blade breast dissector | Oval paddle, rigid build | A firm push where the plane resists |
| Angulated blade breast dissector | Angled blade | A curved chest wall reached from a distance |
| Reynolds transaxillary breast dissector | 15.5 in, 38 mm blade, no insulation | A wide sweep at reach without cautery |
Surgeons who use this pattern usually also hold the oval spatulated blade breast dissector, the angulated blade breast dissector and the Reynolds transaxillary breast dissector. The closest relative in the range is the oval spatulated blade breast dissector.
If you are building a breast tray from scratch, the usual answer is two dissectors rather than one. Something long for the far edge of the pocket and something shorter with more feel at the tip covers almost every case.
Materials and finish
The instrument is made in high quality medical grade stainless steel. The steel itself is made to a German specification. The working face is ground and satin finished, which cuts glare under the lights in an operating room and keeps the end readable against wet tissue. There is no coating to chip and nothing on the shaft to trap protein.
Stainless steel is chosen here for a reason that has nothing to do with appearance. A long shafted dissector is pushed hard at full extension, and a shaft that is too soft will take a set and stay bent, which throws the blade out of the plane on the next pass. A shaft that is too hard will crack at the neck instead. The grade used sits between the two.
Spatulated blade breast dissector care and sterilization
Rinse the instrument in cool water straight after use so blood does not dry on it. Clean it with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, then dry it completely. Steam autoclave at 134 degrees Celsius. Lay it flat in the tray with nothing resting across it, because an instrument loaded sideways in a crowded tray is the one that comes back out of true.
Look at the working end against the light before every case. A blunt end should be smooth with no flat spot and no nick, and the shaft should still be straight when you sight down it. A dissector with a nick on the end is what tears a pocket two cases later, and it costs nothing to check.
Ordering and wholesale
This pattern is supplied by Adas Instruments to hospitals, surgical distributors and OEM buyers, in single units and in bulk. The item code is AN-09.117 and it is printed in the size table above so a procurement search finds it. Backorder items dispatch in 10 to 12 working days. Every instrument carries a three year replacement against manufacturing defects.
For wholesale and OEM orders, instruments ship unpackaged in bulk or individually poly bagged, and laser marking with a distributor code or a hospital asset number is available. Tell us the quantity and the marking you need and the quotation comes back with the lead time for that run.
Production is controlled under an ISO 13485 quality management system. The instrument is CE marked.
Frequently asked questions
What is a spatulated blade breast dissector used for?
It creates and shapes the implant pocket in breast augmentation and reconstruction. The flat paddle blade maximizes the surface in contact with the plane, so connective tissue is separated and pectoralis major is lifted without any sharp edge being involved.
What does spatulated mean on a surgical instrument?
That the working end is flattened and broadened into a paddle, like the blade of a spatula. It is a shape word, not a brand, and catalogues use it for any instrument with that flat broad face.
Insulated or non insulated shaft, which do I need?
Insulated if cautery is used inside the pocket. The insulation keeps the current in the shaft so it only leaves at the tip, which prevents a burn at the incision. Non insulated is for blunt work only.
Is a breast spatula the same thing?
Surgeons use the two names for the same shape, so yes in normal conversation. If you are ordering, the catalogue term is spatulated blade breast dissector and that is what will find it.
How do you clean and sterilize a spatulated dissector?
Rinse in cool water straight after use, clean with a soft brush and a neutral pH enzymatic detergent, rinse in deionized water, dry fully, then steam autoclave at 134 degrees Celsius. On an insulated build, check the insulation along the whole shaft before every case.
Related products and categories
Surgeons who work with the Spatulated blade breast dissector usually compare it against the oval spatulated blade breast dissector, the angulated blade breast dissector and the Reynolds transaxillary breast dissector. It sits beside the MacCollum Dingman breast dissector on the same tray. The whole family sits in dissectors and elevators, and this pattern is also listed under breast surgery instruments.








Reviews
There are no reviews yet.